Press the Scroll buttons (12) until the actual dew point temperature appears.
Warning screen, dew point temperature
Above screen shows that the dew point temperature is 9˚C.
It remains possible to scroll through other screens (using Scroll buttons (12)) to check the actual status of
other parameters.
Press the Stop button (11) to stop the compressor
Switch off the voltage, inspect the compressor and remedy if necessary.
The warning message will disappear as soon as the warning condition disappears.
3.6 Shut-down
Description
The compressor will shut down in following cases:
When the compressor element temperature exceeds the warning level repeatedly.
In case of error of the outlet pressure sensor.
In case of overload of the drive motor.
Note:
If the compressor is equipped with a phase sequence relay, the motor will not start if the phase sequence is
incorrect.
Compressor element temperature
If the compressor element temperature exceeds the programmed shutdown level repeatedly, the
compressor will shut down, warning LED (5) will flash, automatic operation LED (3) will go out and
the following screen will appear:
Main screen with shutdown indication, compressor element temperature