Press the Scroll buttons (12) until the actual compressor element temperature appears.
Shutdown screen, compressor element temperature
In above example, the screen shows that the compressor element temperature is 95 ˚C.
In such case,
Switch off the voltage and remedy the trouble.
After remedying and when the shutdown condition has disappeared by pressing the Escape button
(14) for a reset, switch on the voltage and restart the compressor.
Motor overload
In the event of motor overload, the compressor will shut down, warning LED (5) will flash, automatic
operation LED (3) will go out and the following screen will appear:
Main screen with shutdown indication, motor overload
In such case,
Switch off the voltage and remedy the trouble.
After remedying and when the shutdown condition has disappeared by pressing the Escape button
(14) for a reset, switch on the voltage and restart the compressor.
Phase sequence incorrect
If the compressor is equipped with a phase sequence relay, the motor will not start if the phase sequence is
incorrect. Warning LED (5) will flash, automatic operation LED (3) will go out and the following screen
will appear: