Product Manual
Table Of Contents
- Table of contents
- 1 Safety precautions
- 2 General description
- 3 Elektronikon controller
- 3.1 General description
- 3.2 Control panel
- 3.3 Icons used on the display
- 3.4 Main screen
- 3.5 Shut-down warning
- 3.6 Shut-down
- 3.7 Service warning
- 3.8 Scrolling through all screens
- 3.9 Calling up element and dew point temperatures
- 3.10 Digital inputs
- 3.11 Calling up running hours
- 3.12 Calling up motor starts
- 3.13 Calling up module hours
- 3.14 Calling up/resetting the service timer
- 3.15 Selection between Local, Remote or LAN control
- 3.16 Calling up/modifying CAN address control
- 3.17 Calling up/modifying IP, Gateway and Subnetmask
- 3.18 Calling up/modifying pressure band settings
- 3.19 Modifying pressure band selection
- 3.20 Calling up/modifying service timer settings
- 3.21 Calling up/modifying unit of temperature
- 3.22 Calling up/modifying unit of pressure
- 3.23 Automatic restart after voltage failure
- 3.24 Activating password protection
- 3.25 Calling up/modifying protection settings
- 3.26 Test screens
- 3.27 Web server
- 3.28 Programmable settings
- 4 Elektronikon Graphic Controller
- 4.1 General
- 4.2 Control panel
- 4.3 Icons used
- 4.4 Main screen
- 4.5 Calling up menus
- 4.6 Shutdown warning
- 4.7 Shutdown
- 4.8 Inputs menu
- 4.9 Outputs menu
- 4.10 Counters
- 4.11 Control mode selection
- 4.12 Service menu
- 4.13 Setpoint menu
- 4.14 Event history menu
- 4.15 General settings menu
- 4.16 Info menu
- 4.17 Week timer menu
- 4.18 Test menu
- 4.19 User password menu
- 4.20 Web server
- 4.21 Programmable settings
- 5 Installation
- 6 Operation
- 7 Preventive maintenance
- 8 Adjustments and servicing procedures
- 9 Problem solving
- 10 Technical data
- 11 Instructions for use
- 12 Guidelines for inspection
- 13 Pressure equipment directives
- 14 Declaration of conformity
Digital input
screens
Designation Related topic
<d.2> Motor starts (x 1 or x 1000) See section Calling up motor starts
<d.3> Module hours (hrs or x 1000 hrs) See section Calling up module hours
<d.4> Service timer reading (hrs or x 1000 hrs) See section Calling up/resetting the service
timer
<d.7> Actual program version -
Parameter
screens
Designation Related topic
<P.1> Selection between local, remote or LAN
control
See section Selection between Local,
Remote or LAN control
<P.2> Setting a node ID for LAN control and the
channels for Mk 4 and Mk 5
See section Calling up/modifying CAN
address control
<P.3> Settings for IP, gateway and Subnet mask See section Calling up/modifying IP
Gateway and Subnetmask
<P.4> Pressure band settings See section Calling up/modifying pressure
band settings
<P.5> Setting a pressure band selection See section Modifying pressure band
selection
<P.6> Modifying a service timer See section Calling up/modifying service
timer settings
<P.7> Setting the unit for temperature See section Calling up/modifying unit of
temperature
<P.8> Setting the unit for pressure See section Calling up/modifying unit of
pressure
<P.9> Selection for function: Automatic restart
after voltage failure (active or not, only for
Atlas Copco)
See section Activating automatic restart
<P.10> Selection between Y-D or DOL starting (not
applicable)
-
<P.11> Setting of minimum stop time (not
applicable)
-
<P.12> Setting a password See section Activating password protection
<P.13> Remote pressure sensing (not applicable) -
Protections
screens
Designation Related topic
<Pr.3> Protections screens See section Calling up/modifying protection
settings
Test screens Designation Related topic
<t.1> Display test See section Test screens
<t.2> Safety valve test See section Test screens
<t.3> Drain test (not applicable)
Instruction book
2920 7110 21 35