Product Manual
Table Of Contents
- Table of contents
- 1 Safety precautions
- 2 General description
- 3 Elektronikon controller
- 3.1 General description
- 3.2 Control panel
- 3.3 Icons used on the display
- 3.4 Main screen
- 3.5 Shut-down warning
- 3.6 Shut-down
- 3.7 Service warning
- 3.8 Scrolling through all screens
- 3.9 Calling up element and dew point temperatures
- 3.10 Digital inputs
- 3.11 Calling up running hours
- 3.12 Calling up motor starts
- 3.13 Calling up module hours
- 3.14 Calling up/resetting the service timer
- 3.15 Selection between Local, Remote or LAN control
- 3.16 Calling up/modifying CAN address control
- 3.17 Calling up/modifying IP, Gateway and Subnetmask
- 3.18 Calling up/modifying pressure band settings
- 3.19 Modifying pressure band selection
- 3.20 Calling up/modifying service timer settings
- 3.21 Calling up/modifying unit of temperature
- 3.22 Calling up/modifying unit of pressure
- 3.23 Automatic restart after voltage failure
- 3.24 Activating password protection
- 3.25 Calling up/modifying protection settings
- 3.26 Test screens
- 3.27 Web server
- 3.28 Programmable settings
- 4 Elektronikon Graphic Controller
- 4.1 General
- 4.2 Control panel
- 4.3 Icons used
- 4.4 Main screen
- 4.5 Calling up menus
- 4.6 Shutdown warning
- 4.7 Shutdown
- 4.8 Inputs menu
- 4.9 Outputs menu
- 4.10 Counters
- 4.11 Control mode selection
- 4.12 Service menu
- 4.13 Setpoint menu
- 4.14 Event history menu
- 4.15 General settings menu
- 4.16 Info menu
- 4.17 Week timer menu
- 4.18 Test menu
- 4.19 User password menu
- 4.20 Web server
- 4.21 Programmable settings
- 5 Installation
- 6 Operation
- 7 Preventive maintenance
- 8 Adjustments and servicing procedures
- 9 Problem solving
- 10 Technical data
- 11 Instructions for use
- 12 Guidelines for inspection
- 13 Pressure equipment directives
- 14 Declaration of conformity
Starting from the Main screen, press the Scroll buttons (12) until <P. 1> is shown and then press the Enter
button (13). The actually selected control mode is shown: <LOC> for local control, <rE> for remote
control or <LAn> for LAN control.
To change: press the Enter button (13) and - if necessary - enter the password (see section Activating
password protection). The actually selected control mode is blinking. Use the Scroll buttons (12) to change
the control mode. Press the Enter button (13) to program the new control mode or press the Escape button
(14) to cancel.
3.16
Calling up/modifying CAN address control
Calling up
Starting from the Main screen, press the Scroll button (12) until <P. 2> is shown and then press the Enter
button (13).
If necessary enter the password. The next screen shows that the function is ON or OFF. Press the Enter
button (13) to change this mode. Use the Scroll buttons (12) to select <On> or <OFF> and press Enter to
program.
When this function is ON, use the Scroll buttons up or down (12) to see the node ID.
Modifying the Node ID
The Node ID can be changed; use a value between 1 and 31. When the function is ON, the parameters
cannot be modified. Change the function to OFF to change the node ID.