User manual

2920 1475 00
13
Instruction book
Fig. 1.11 Menu flow
Compressor Outlet 6.4 bar
Automatically Loaded
Menu Unload
Automatic Operation
Local Control
Week Timer Active
Mainscreen Help Extra
Maximum Pressure 8.3 bar
Running Hours 1016 hrs
Loaded Hours 980 hrs
Mainscreen Help Extra
Status Data
Measured Data
Counters
Mainscreen
All Conditions Are OK
Menu Help
Status Data
Measured Data
Counters
Mainscreen
Compressor Outlet 5.4 bar
Dp Oil Separator 1.1 bar
Dp Air Filter 0.02 bar
Menu
Measured Data
Counters
Test
Mainscreen
Counters
Test
Modify Parameters
Mainscreen
Test
Modify Parameters
Service
Mainscreen
Modify Parameters
Service
Saved Data
Mainscreen
Running Hours 1016 hrs
Loaded Hours 980 hrs
Motor Starts 945 number
Menu
Loading Pressure 6.4 bar
Unloading Pressure 7.0 bar
Loading Pressure 2 6.0 bar
Menu Modify
Compressor Outlet 5.4 bar
Dp Oil Separator 1.1 bar
Dp Air Filter - 0.011 bar
Menu
Parameters
Protections
Service Plan
Menu
Service Timer
Running Hours
130 hrs
Menu
Service Timer
Running hours
130 hrs
Menu
Modify Parameters
Service
Saved Data
Mainscreen
Last Shutdown 1
Last Shutdown 2
Last Shutdown 3
Menu
52407PEN
Service Plan
Clock Function
Configuration
Menu
Clock Function
Not Activated
Menu Modify Delete
Time 10:54
Date 03/05/01
Date Format DD/MM/YY
Menu Modify
-Motor Starts
-Module Hours
-Load Relay
-Compressor Outlet
-Dp oilseparator
-Dp Air Filter
-Oil injection element
-Compressor Outlet
-Element 1 Outlet
-Element 2 Outlet
-Cooling medium
-Oil Injection Element
-Compressor Outlet
-Element 1 Outlet
-Element 2 Outlet
-Cooling Medium
-Oil Separator
-Dryer LAT
-Emergency Stop
-Remote Start/Stop
-Remote LoadUnload
-Remote pressure sensing
-Overload Motor
-Overload Fanmotor
-Starter Feedback Contact
-PB1 open/ PB2 closed
-Overload Dryer/Dryer Fan
-Module Hours
-Load Relay
-Unloading Pressure 2
-Y-Time
-Load Delay
-Nr Of Starts/ Day
-Minimum Stop Time
-Programmed Stop Time
-Permisive Start Time
-Communication Time-out
Display Test
Safety Valve Test
Menu
-Oil Injection Element
-Compressor Outlet
-Element 1 Outlet
-Element 2 Outlet
-Cooling Medium
-Oil Separator
-Dryer LAT
-Emergency Stop
-Remote Start/Stop
-Remote Load/Unload
-Remote Pressure Sensing
-Overload Motor
-Overload Fanmotor
-Starter Feedback Contact
-PB1 open/ PB2 closed
-Overload Dryer/Dryer Fan
-Language In Use
-Pressure Unit
-Temperature Unit
-Vibration Unit
-Level Unit
-Pressure Band Used
-Start Mode
-CCM (control mode)
-Automatic Restart
-Password
-Node ID
-Digital Presband Selec.
Service Plan
Clock Function
Configuration
Menu
Parameters
Protections
Service Plan
Menu
-Oil separator
-Dryer LAT
-Emergency Stop
-Remote Start/Stop
-Remote Load/Unload
-Remote pressure sensing
-Overload Motor
-Overload Fanmotor
-Starter Feedback Contact
-PB 1 open/ PB2 closed
-Overload dryerdryer fan
Protections
Service Plan
Clock Function
Menu