User manual

2920 1475 00
24
Instruction book
Ref. Description
1 Install the compressor on a level floor suitable for taking
the weight of the compressor. For ventilation proposal
1, the minimum distance between the top of the
bodywork and the ceiling is 1200 mm.
2 Remove the plastic plug (if provided) from the
compressor air outlet pipe (3-Fig. 3.5/7-Fig. 3.6) and
fit the air outlet valve 1) to the pipe. Close the valve
and connect it to the net.
Ref. Description
3 The pressure drop over the air outlet pipe can be
calculated as follows:
dp = (L x 450 x Qc
1.85
) / (d
5
x p)
dp = pressure drop (recommended maximum =
0.1 bar)
L = length of outlet pipe in m
d = inner diameter of the outlet pipe in mm
p = absolute pressure at the compressor outlet in
bar(a)
Qc = free air delivery of the compressor in l/s
Fig. 2.10 Installation proposal, GA200 W up to GA315 W