User manual

2920 1475 00
35
Instruction book
2. To stop the compressor in case of emergency, press button
(S2-Fig. 3.8). Alarm LED (7) blinks. After remedying the
fault, unlock the button by pulling it out.
3. Close air outlet valve (3-Fig. 3.5/7-Fig. 3.6).
4. Open condensate drain valves (1 and 2-Fig. 3.7). 2)
5. On GA W, close the water shut-off valves 6).
6. On GA W, if the compressor is installed in a room where
freezing temperatures are expected, drain the cooling
system by opening the drain valves in the water inlet and
outlet pipes (customer's installation).
7. Switch off the voltage.
Example: ambient temperature 20 degrees Celsius, relative humidity 100 % and working pressure 10 bar(e). The minimum
allowable temperature at the outlet of the compressor elements is 68 degrees Celsius. Regulate the cooling water flow to obtain
a temperature between 70 and approx. 75 degrees Celsius at the outlet of the compressor elements.
Fig. 3.9 Minimum allowable air temperature at outlet of compressor elements (for water-cooled compressors)
1 Water outlet
2 Water inlet
3 Combined oil and air coolers
4 Regulating valve, water flow
Fig. 3.10 Water system of GA W (typical example)
2
1
3
4
50847F