User manual
2920 1475 00
40
Instruction book
The system includes an OSD315 oil/water separator (shown at
the left) connected to the condensate trap downstream of the
air cooler. The condensate is led from the condensate trap
through inlet (4) and filter (5) towards water vessel (3) where
the oil rises due to the difference in specific mass. The water
flows through condensate outlet (1) to the outside of the
bodywork. The oil flows into collector (6), which must be
emptied regularly.
For Full-feature compressors, the system also includes an
OSD90 (shown at the right) connected to the dryer condensate
trap. OSD90 are additionally provided with a pre-filter (7)
and a pressure gauge (8).
Servicing procedure
1. Stop the compressor, press emergency stop button (S2-Fig.
3.8) and switch off the voltage.
2. Close the outlet valve and open the valve underneath the
air cooler condensate trap.
3. Oil the gaskets of the new filters, fill the filters with water
and fit them.
4. On OSD90, unscrew the pre-filter housing, fit a new pre-
filter and fit the housing using a new O-ring.
5. Inspect the strainer/restrictors at the inlet of the separator
vessels, clean and reinstall them. Close the valve underneath
the condensate trap.
6 PROBLEM SOLVING
Warning Before carrying out any maintenance, repair or
adjustment, stop the compressor, press emergency
stop button (S2-Fig. 3.8) and switch off the
voltage. Close the air outlet valve and open the
manual condensate drain valve(s). 1)
Take precautions to avoid an accidental restart.
Apply all relevant safety precautions, including
those mentioned in this book.
Faults and suggested remedies
1 A shut-down warning message appears on the display
LED (7-Fig. 3.8) will light up indicating that the temperature
at the outlet of the compressor elements is too high. See
below. The message disappears as soon as the cause of the
trouble is remedied
2 Unit is shut down
LED (7-Fig. 3.8) will blink indicating either that the outlet
temperature is too high (see below) or that the motor
overload relay has tripped. Consult the "User manual for
Elektronikon regulator" to remedy the trouble and to reset
the message (section "Submenu STATUS DATA")
3 Condensate is not discharged from condensate trap(s)
during loading
a Discharge pipe of condensate trap clogged
a Check and correct as necessary
b Float valve of condensate trap(s) malfunctioning
b Remove float valve assembly, clean and check
5 Compressor air delivery or pressure below normal
a Air consumption exceeds air delivery of compressor
a Check equipment connected
b Choked air filters
b Replace filters
c Air leakage
c Check and correct
6 Compressor element outlet temperature or delivery air
temperature above normal
a Insufficient cooling air
a Check for cooling air restriction. Improve ventilation of
compressor room. Avoid recirculation of cooling air
b On GA W, cooling water temperature too high or flow too
low
b See section 7.5. Increase water flow and check temperature
1 Water outlet
2 Oil outlet
3 Water vessel
4 Condensate inlet
5 Filter
6 Oil collector
7 Pre-filter
8 Pressure gauge
Fig. 5.1 OSD90/315 oil separators (option)
Footnote chapter 6
1) On compressors with optional OSD separator, a valve is fitted
underneath the condensate trap. Close the valve after repairing.
1