User manual

2920 1461 03
25
User manual
11.1 Modifying settings for compressor
element
1. Consult the section above to select the parameter Element
outlet:
Element Outlet
C94®
Shd Max 120
Menu Mod ¯
F1 F2 F3
Fig. 11.1 Modify parameters menu
2. The screen shows that the current temperature is 94 degrees
Celsius and that the shut-down setting is 120 degrees
Celsius. To modify this setting, press the key Mod (F2):
Element Outlet
C 120 (blinks)
Prog Lim Canc ¯
F1 F2 F3
Fig. 11.2 Modify parameters menu
3. The key Lim (F2) can be used to find the limitations for
the parameter. Use the ¯ or arrow key to change the
value.
4. Press the key Prog (F1) to program the new setting or the
key Canc (F3) to cancel the modification operation.
5. The screen shown in Fig. 11.1 shows an arrow pointing to
the right to call up the screen to modify the shut-down
warning value:
Element Outlet
C94
Shdw Max 110
Back Mod
F1 F2 F3
Fig. 11.3 Modify parameters menu
6. The screen shows that the current temperature is 94 degrees
Celsius and that the shut-down warning setting is 110
degrees Celsius. The modifying procedure is similar to the
description above.
Note:
The modifying procedure for other settings is similar. For some
settings, a delay can be programmed. See section 17.
12 Modifying service plans
Function
To modify the hour intervals for the Service plans.
Service plans
The service operations to be carried out are grouped in plans
called Service plan A, B, C or D. Consult section 4 in the related
Instruction book. When reaching an interval, a message will
appear on the screen indicating which Service plans are to be
carried out.
Important
Always consult Atlas Copco in case any timer setting should
be changed. The intervals must not exceed the periods below
and must coincide logically.
Programmed service plan intervals
Service plans Intervals
Service plan A Each 4000 running hours
Service plan B Each 4000 running hours
Service plan C Each 8000 running hours
Service plan D Each 40000 running hours
Resulting service actions to be carried out
Service actions according to At
Service plan A and B 4000 running hours
Service plan A, B and C 8000 running hours
Service plan A and B 12000 running hours
Service plan A, B and C 16000 running hours
.
52237F
8
11
710
612
3
2
1
9
4
5
4
9
S3
9