Manual

The installation location shall be reasonably away from the fire source.
The installation location shall not be accessible by the children.
The installation location shall be sufficiently away from water sources, such as water
tap, sewer pipe, sprinkler etc., to avoid water infiltration.
The installation wall shall be strong enough to carry the weight of the battery for a
long time, please follow local standard or best practice guidelines.
Do not place inflammables and explosives around the battery.
When the battery is running, do not block the vent or cooling system. Maintain the
batter y operating temperature for charging 0-55 ? and discharging - 20 ~ 60 ?.
Do not store or install the battery in an environment of flammable or explosive gas or
smoke. Any operation of the battery in such environment is strictly prohibited.
The battery can be installed on a vertical or backward inclined plane. Please refer to the
following figure:
In order to ensure good heat dissipation and convenience in operation and
maintenance, sufficient clearance shall be reserved while installing the battery. An example
of such clearances are shown in the figure below. Please strictly follow the local battery
installation guidelines, where applicable.
9
ESI
+
-
ESI
+
-
ESI
+
-
ESI
+
-
ESI
+
-
30cm 30cm
30cm
30c m