Manual

If the equipment has multiple inputs, all inputs of the equipment shall be
disconnected, and the equipment can be operated only after the equipment is
completely powered off.
Wiring requirements
The use of the cable in high temperature environment may cause aging and damage
of the insulating layer. The distance between the cable and the periphery of the
heating device or heat source area shall be at least 30mm.
Similar cables shall be bound together, and different types of cables shall be laid at
least 30mm apart. Mutual winding or cross laying is prohibited.
The cables used must be firmly connected, well insulated and of appropriate
specifications.
2.Product introduction
2.1 Product introduction
Function
Li-ion battery includes only batter y modules, which can store
and release electric energy according to the requirements of inverter management
system. The input and output ports of battery are 48 / 51.2V DC.
◆ Battery charging: the power control module is connected with the energy storage
terminals (BAT +, bat -) of the inverter to charge the battery and store the excess
photovoltaic energy in the battery under the control of the inverter.
◆ Battery discharge: when the photovoltaic energy is insufficient to supply power to the
load, the system needs to control the battery to supply power to the load and output
the stored battery energy to the load through the inverter.
Model
5
NO.
Voltage
ESI
Capacity
IP Level
1
48V
IP20
Bluetooth
WIFI
GSM
160/220Ah