OWNER'S MANUAL AA-PPRC AA-PPRC PRIORITY PAGING REMOTE CONTROLLER Specifications are subject to change without notice www.AtlasSound.com 1601 JACK MCKAY BOULEVARD ENNIS, TEXAS 75119 U.S.A. • © 2007 ATLAS SOUND LP Printed in U.S.A.
OWNER'S MANUAL AA-PPRC ATLAS SOUND AA-PPRC PRIORITY PAGING REMOTE CONTROLLER TABLE OF CONTENTS 1.0 Important Safety Instructions .................................................................. 3 2.0 Introduction ............................................................................................. 4 3.0 Connection and Adjustment Identification .............................................. 5 4.0 Specifications ........................................................................................
OWNER'S MANUAL AA-PPRC 1.0 IMPORTANT SAFETY INSTRUCTIONS The lightning flash with arrowhead symbol within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage “ within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
OWNER'S MANUAL AA-PPRC WARNING • • • • • • • • • • • WHEN THE DEVICE IS IN USE To prevent electric shock, do not remove the product cover as there are high voltage components inside. Refer all servicing to Atlas Sound. Should any of the following irregularities occur during use, immediately switch off the power, disconnect the power cord from the AC outlet and contact Atlas Sound.
OWNER'S MANUAL AA-PPRC 3.0 CONNECTION AND ADJUSTMENT IDENTIFICATION 1 12 2 11 10 3 4 5 6 7 8 9 1. Amplifier Input - Normally Closed Relay Contacts (NC) Connect an amplifier power output to this input if you need the amplifier load to be disconnected when the trigger circuit is activated. Note: “NC” stands for Normally Closed relay contacts, thus meaning it WILL pass signal thru to the relay output contacts without power or circuit activation.
OWNER'S MANUAL AA-PPRC 5. Trigger Delay Adjustment This screw driver adjust potentiometer determines the amount of time needed to keep the circuitry activated to complete a page. Follow the indicator arrow to adjust the time. Note: There are a few milliseconds of delay even if the unit is set to zero. It is suggest not to set to Zero for paging application due to pauses in ones message during a page. This will prevent annoying repeated triggering before a page is completed. 6.
OWNER'S MANUAL AA-PPRC POWER HANDLING CHART AA-PPRC LOAD RATING 5 Amps. Max Per Channel Load Watts Amps 100V (20 Ω) 500 W 5 Amps. 70V (14 Ω) 350 W 5 Amps. 25V (5 Ω) 125 W 5 Amps. 8Ω 200 W 5 Amps. 4Ω 100 W 5 Amps. 2Ω 50 W 5 Amps.
OWNER'S MANUAL AA-PPRC 4.0 SPECIFICATIONS Type Speaker Line Remote Switcher Channels 2 Circuit Design Relay Switching Load Rating Watts 350 W @ 70V (See Load Chart for other Load Ratings) Load Rating Amps 5 Amps. per channel MAX Indicators One Bi-color LED Red/Green Inputs Qty. 4 Four Position Detachable Phoenix Connectors Maximum Input Level 100V AC Outputs Qty.