Filters
High Shelf Filter - Increase / decrease frequencies above target Frequency (20Hz to 20kHz, 1 Hz steps) by the EQ Level (-30 to +15dB,
0.1dB steps). Roll off controlled by the Bandwidth (0.01 to 4.00oct, 0.01 steps) setting. Bypass feature included.
Low Shelf Filter - Increase / decrease frequencies below target Frequency (20Hz to 20kHz, 1 Hz steps) by the EQ Level (-30 to +15 dB,
0.1dB steps). Roll off controlled by the Bandwidth (0.01 to 4.00oct, 0.01 steps) setting. Bypass feature included.
All Pass Filter: First Order - Unity gain filter with 180 deg. phase shift over dynamic range, phase shift of Degree (0 to 179.5, 0.5
steps) at target Frequency (20Hz to 20kHz, 1 Hz steps). Bypass feature included.
Fig 80
Fig 81
Fig 82