Counter - Each trigger (low-to-high signal) at the Trigger I/O adds one to the Count (0 to 99999999), at Threshold (0 to 99999999) the
output state becomes high. State indicates the current output condition. Use Force Trigger to add one to the count total. Force Reset
and a trigger (low-to-high signal) at the Reset I/O will reset the Count value to zero.
Delay Hold - When the input is triggered (low-to-high signal) or the Force Trigger button is used the Delay I/O will activate for the
Delay Time (0.01 to 5000s) as can be seen by the Delay State. After the Delay Time, The Hold I/O will activate for the Hold Time (0.01 to
5000s) depicted by the Hold State. Loop Mode will continously cycle the Delay and Hold for one input trigger (low-to-high signal). Use
the Reset button to reset and Force trigger to activate the module. Allow Trigger sets whether a new trigger can occur during an event
(Delay and Hold active cycle).