Manual

– 7 – AtlasSound.com
Specifications are subject to change without notice.
Owner’s Manual
DPA-102PM - Networkable 2-Channel
Power Amplifier with DSP
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
Rear Panel Description
1. IEC AC Receptacle
The included IEC cord is designed to work with 110-120VAC. A separate IEC cord will need to be purchased for 220-240VAC operation.
2. AC Mains Fuse
Replaceable 2A, 250V fuse.
3. RCA Input
Unbalanced signals are accepted via the Ch 1 & Ch 2 RCA connectors.
4. Balanced Input Connections
Ch 1 & Ch 2 balanced input signals are accepted via the removable Phoenix type connector per the labeling on the rear of the amp.
Note: For unbalanced signals connect the (–) and (GND) pins together.
5. Speaker Connection
A removable Phoenix type connector is supplied to connect your speakers to the DPA-102PM. It is recommended to use class 3 rated,
16-gauge wire or higher for speaker wiring.
Note: Do not overload the amp by connecting too many speakers to the amp. Four Ω per channel is the minimum average impedance.
6. Remote Level Control
Remote location of the level control can be
accomplished via the Remote Level control port on the
DPA-102PM The control port is 10KΩ based system. It
is recommended the optional Atlas Sound WPD-VC10K
wall control be used. Set the system’s maximum levels
using the amplifier level controls and then use the
remote 10KΩ potentiometer as an attenuator. Wiring
the WPD-VC10K will require using three conductor
unshielded wire connecting the WPD terminals to the
amp. Maximum distance can be up to 500 feet.
Note: Each channel of the DPA-102PM can be
controlled separately or together.
7. Ethernet Port
Connect the amplifier to the network or local computer using CAT5 cable to access amplifier’s DSP and control settings.
Remote control the audio levels via VCA technology. Connect one side of a 10K linear tape pot to the terminal marked DC10V, the
other side of the pot to the (G) terminal, and the wiper to the Control 1 terminal. Control 1 will adjust input channel 1 and Control 2 will
adjust input channel 2.w
6 57 14 3 2
per channel is the minimum average impedance.