Owner’s Manual ECM-RACEWY ECM-20, ECM-20M, & ECM-30 ECM-RACEWY6/3/1 Module Housing ECM-20, ECM-20M, & ECM-30 Sequencer Modules ECM-RACEWY6 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800.876.3333 • Fax: 800.765.3435 – 1 – Specifications are subject to change without notice. AtlasSound.
ECM-RACEWY ECM-20, ECM-20M, & ECM-30 Owner’s Manual Table of Contents Important Safety Instructions................................................................................................................... 3 Introduction ............................................................................................................................................ 5 ECM-RACEWY Key Features.......................................................................................................
Owner’s Manual ECM-RACEWY ECM-20, ECM-20M, & ECM-30 Important Safety Instructions The lightning flash with arrowhead symbol within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage “ within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
ECM-RACEWY ECM-20, ECM-20M, & ECM-30 • • • • • • • • • • • • • • • • • • • Owner’s Manual WARNING When The Device Is In Use To prevent electric shock, do not remove the product cover as there are high voltage components inside. Refer all servicing to Atlas Sound. Should any of the following irregularities occur during use, immediately switch off the power, disconnect the power cord from the AC outlet and contact Atlas Sound.
Owner’s Manual ECM-RACEWY ECM-20, ECM-20M, & ECM-30 Introduction Thank you for purchasing the Atlas Power Electrical Control Module Raceway system. This manual is divided up into two main sections, the ECM-RACEWY housing and the ECM-20, ECM-20M, and ECM-30 modules. This manual will explain which ECM module to choose for your application, how to configure it, and how to wire it. Note: For your safety all electrical wiring must be done by a qualified electrician.
ECM-RACEWY ECM-20, ECM-20M, & ECM-30 Owner’s Manual ECM-RACEWY Key Features • ECM-RACEWY6 Holds Up To 6 ECM-20, ECM-20M, or ECM-30 Modules • ECM-RACEWY3 Holds Up To 3 ECM-20, ECM-20M, or ECM-30 Modules • ECM-RACEWY1 Holds 1 ECM-20, ECM-20M, or ECM-30 Module • 4 AC Inlet Locations • Dual Knockouts ½" & ¾" • 4 (ECM-RACEWY6 & ECM-RACEWY3) or 2 (ECM-RACEWY1) Breakaway Rail Mounting Tabs • Blank Module Cover Plates for ECM-RACEWY6 (2 included) • 2 Locations for Ch
ECM-RACEWY ECM-20, ECM-20M, & ECM-30 Owner’s Manual Raceway ECM Housing The ECM-20, ECM-20M, and ECM-30 require an electrical housing. The ECM-RACEWY6 holds up to 6 ECM modules, while the ECM-RACEWY3 holds up to 3 ECM modules, and the ECM-RACEWY1 holds 1 ECM module. There are standard 1⁄2" and 3⁄4" dual knockouts on the bottom of the raceway to support standard electrical mounting hardware.
ECM-RACEWY ECM-20, ECM-20M, & ECM-30 Owner’s Manual Raceway AC Ground Stud The ECM-RACEWY has an internal AC Mains chassis stud for GROUND connection. The stud size is 10⁄32" x 1". A nut and star washer are also supplied. The second figure on page 7 shows the internal location of the stud. Raceway Mounting Rails The ECM-RACEWY can be mounted into most racks. The raceways have bendable mounting tabs that make them convenient to secure in most applications.
ECM-RACEWY ECM-20, ECM-20M, & ECM-30 Owner’s Manual ECM-20 & ECM-20M Front Panel Features 4 1 3 5 2 6 1 4 3 2 1. Trigger/Status Port Pin Identification All signals are of low voltage and current. DO NOT MISS WIRE or damage may occur. 6 A. (+) Requires a minimum of 5 - 24V DC to activate the module with 5mA of current. Note: The DCV can be supplied from any source. The EVS protection requires the ECS-6RM for operation. B.
ECM-RACEWY ECM-20, ECM-20M, & ECM-30 Owner’s Manual ECM-30 Front Panel Features 3 1 4 5 2 7 6 1. Trigger/Status Port Pin Identification All signals are of low voltage and current. DO NOT MISS WIRE or damage may occur. A. (+) requires a minimum of 5–24V DC to activate the module with 5mA of current. Note: The DCV can be supplied from any source. The EVS protection requires the ECS-6RM for operation. B. G = Circuit Ground. Must be of the same circuit as the DCV source. C.
ECM-RACEWY ECM-20, ECM-20M, & ECM-30 Owner’s Manual ECM (Electrical Control Modules) Differences Between the ECM-20 & ECM-20M Modules The ECM-20 & ECM-30 do not support the same current monitoring or EMI/RFI Filter feature as the ECM-20M, ECM-20SH and the ECM-15SH models. However, they does support AC Spike and Surge Suppression, AC Mains Voltage monitoring, EVS circuitry, and Remote Activation.
ECM-RACEWY ECM-20, ECM-20M, & ECM-30 Owner’s Manual ECM-3BP Module Blank Cover Plate It is not necessary to have a module installed in every slot of the ECM-RACEWY6 or the ECM-RACEWY3, however, there should be no open slots to prevent the risk of damage or serious injury. ECM Module Black Plates can be used to cover open slots. Two blank plates are included with the ECM-RACEWY6 only. Additional Blank Plates can be purchased in packages of three.
Owner’s Manual ECM-RACEWY ECM-20, ECM-20M, & ECM-30 ECM-20/ECM-20M Module System Wiring Configuration Example 1 - Single 20A AC Line ECM wiring configuration showing one 20A AC main line coming into an ECM-20M then paralleling with five ECM-20 type modules. Note: It appears that the wiring is in series but the ECM Module In/Out terminals are in parallel on the PCB.
ECM-RACEWY ECM-20, ECM-20M, & ECM-30 Owner’s Manual Activating an ECM via ECS-6RM Relay Contacts Each Channel of the ECS-6RM also has a Relay contact that works in conjunction with the ECM control port. Sequencing and timing of these connections are the same as the corresponding ECM channels. Example: Sequence 1 ECM Port output works at the same times CH 1 Relay contact. Note: All ECM modules can be trigger using the Relay contacts to activate the ECM module. See ECM module for details.
Owner’s Manual ECM-RACEWY ECM-20, ECM-20M, & ECM-30 ECM Data Wire and Distance There are six ECM control ports on the ECS-6RM and up to six ECM Modules can be connected to the ECS-6RM. The different types of ECM Modules require the same interface connectivity to the ECS-6RM. All ECM Modules and be interchange with the ECS-6RM. For connection between the ECS-6RM and an ECM module use a 5 conductor cable that is a minimum of 22 gauge wire.
ECM-RACEWY ECM-20, ECM-20M, & ECM-30 Owner’s Manual ECM Troubleshooting Note: ALL TROUBLESHOOTING SHOULD BE DONE BY A CERTIFIED ELECTRICIAN Issue 1 - Incoming AC LED is not illuminated. Possible Cause 1 Incoming AC Mains circuit breaker has tripped due to excessive load. Action Needed Check the AC outlet that the ECM is plugged into for 120V AC voltage. If no voltage is present, check to see if the AC outlet is on a GFI that has been tripped.
ECM-RACEWY ECM-20, ECM-20M, & ECM-30 Owner’s Manual ECM-RACEWY Specifications Type Housing for ECM-20 or ECM-20M modules Mechanical Number of ECM Modules Up to Six (ECM-RACEWY6) Up to Three (ECM-RACEWY3) One (ECM-RACEWY1) Blank Module Plates Qty. 2, Included (ECM-RACEWY6 Only) Electrical Inlets Qty. 4 Electrical Inlet Size 1 Chassis Finish Black Paint Height 5.55" (14.1cm) Width 56.5" (143.5cm) (ECM-RACEWY6) 30.75" (78.11cm) (ECM-RACEWY3) 13.77" (34.
ECM-RACEWY ECM-20, ECM-20M, & ECM-30 Owner’s Manual ECM-20/ECM-20M Specifications Type Power Conditioner Suppressor Module RoHS Compliant Yes Safety Listings MET (UL 1449 Code) Front Panel Outlets Qty.
ECM-RACEWY ECM-20, ECM-20M, & ECM-30 Owner’s Manual ECM-30 Specifications Type Power Conditioner Suppressor Module RoHS Compliant Yes Safety Listings UL 1449 Front Panel Outlet Single 30A, L5-30 AC Mains Circuit Breaker 30A Resettable Indicators Active (Green), Fault (Red), Incoming AC (Red) External Trigger/Manual On Slide Switch Connectors 5 Position Phoenix Euro Block Style Hard Switch Remote Trigger SPST Contact Status Signals Output for Voltage (When used with ECM-6RM
ECM-RACEWY ECM-20, ECM-20M, & ECM-30 Owner’s Manual Limited Warranty All products manufactured by Atlas Sound are warranted to the original dealer/installer, industrial or commercial purchaser to be free from defects in material and workmanship and to be in compliance with our published specifications, if any.