Installation Instructions

StormMaster Slate General Instructions
Atlas Roofing
StormMaster® Slate General Instructions
For Spanish Instructions Click Here (Para
las Instrucciones Españolas Haga Clic Aquí)
IMPORTANT: THE STATEMENTS EXPRESSED ON THIS PAGE ARE THE RECOMMENDATIONS FOR THE
APPLICATION OF THE ROOFING PRODUCTS AS OUTLINED AND ILLUSTRATED. ANY DEVIATION FROM
THESE RECOMMENDED PROCEDURES SHALL BE AT THE SOLE RISK OF THE INSTALLERS. FAILURE TO
FOLLOW THESE INSTRUCTIONS MAY RESULT IN SERIOUS DAMAGE TO THE APPLICATION AND LIFE
OF THIS ROOFING PRODUCT, RESULTING IN THE TERMINATION OF ANY WARRANTY, EXPRESSED OR
IMPLIED.
1.) GENERAL INSTRUCTIONS
The lifetime limited warranty option is only available for individual single-family site built detached
residence. A 50 year limited warranty would apply to all property owned by government agencies,
corporations, limited liability companies, partnerships, trust, religious organizations, schools, or
school districts, condominiums, or cooperative housing arrangements, or installed on apartment
buildings or any type of building or premises not used by individual homeowners for a single family
site built detached residence.
These StormMaster Slate shingles are warranted against manufacturing defects and wind gusts up
to 110 MPH WITH STANDARD 4 NAIL INSTALLATION. See ATLAS SIGNATURE SELECT® LIMITED
WARRANTY FOR HIGH WIND WARRANTY PROVISION (130 MPH). (See DIAGRAM #7 for proper
fastening)
The StormMaster® Slate Limited Warranty can be obtained by visiting
www.AtlasRoofing.com/Warranty, or by writing to: Atlas Roofing Corporation, Attn: Consumer
Service Department, 2564 Valley Road, Meridian, Mississippi, 39307. The following instructions
must be followed to qualify for protection under the StormMaster® Slate Limited Warranty.
Important: See special instructions below for Low Slope Applications. See special instructions below
for Steep Slope/Mansard/130 MPH High Wind application. To obtain stated area coverage and to
achieve design performance and appearance, the directions on this package must be followed.
Sealing of the adhesive strips on each shingle to the shingle beneath is created by heat from
sunlight. Atlas Roofing Corporation also endorses the Asphalt Roofing Manufacturers Association’s
(ARMA) recommendations for application details not specified within this text. DO NOT INSTALL
STORMMASTER® SLATE OVER EXISTING SHINGLES- START WITH A CLEAN DECK, COVERED WITH
APPROVED UNDERLAYMENT.
2.) ROOF DECK VENTILATION
Adequate ventilation under the roof deck must be provided to prevent harmful condensation in
winter and heat build-up in summer. These conditions can cause:
A. Accelerated shingle weathering B. Deck rot and attic fungus C. Shingle distortion/cracking due to
deck movement D. Cosmetic blisters on the shingle surface
Atlas will not be responsible for damage to shingles as a result of inadequate ventilation.
Ventilation provisions must meet or exceed current FHA Minimum Property Standards and conform
to all building codes and regulations. To best ensure adequate ventilation and circulation of air, a
1 / 9