1. GENERAL INSTRUCTIONS
These GlassMaster shingles are warranted against manufacturing defects and wind gusts up to 60
MPH. The GlassMaster® 30 Limited Warranty can be obtained by visiting
www.AtlasRoofing.com/Warranty, or by writing to: Atlas Roofing Corporation, Attn: Consumer
Service Department, 2564 Valley Road, Meridian, Mississippi, 39307. The following instructions
must be followed to qualify for protection under the GlassMaster® 30 Limited Warranty.
Important: See special instructions below for Low Slope Applications. See special instructions below
for Steep Slope/Mansard/ High Wind application. To obtain stated area coverage and to achieve
design performance and appearance, the directions on this package must be followed. Sealing of
the adhesive strips on each shingle to the shingle beneath is created by heat from sunlight. Atlas
Roofing Corporation also endorses the Asphalt Roofing Manufacturers Association’s (ARMA)
recommendations for application details not specified within this text.
Important: Do not apply GlassMaster® 30 shingles on roofs having a slope less than 2" per ft. See
special instructions for Low Slopes (2" to 4" per ft.) and for Steep Slope/Mansard/High Wind
application. To obtain stated area coverage and to achieve design performance and appearance,
the directions on this package must be followed. Sealing of the adhesive strips on each shingle to
the shingle beneath is created by heat from sunlight. Sealing may be delayed if shingles are
applied during cooler temperatures, or to roof areas that do not receive direct sunlight. Dust
accumulation may also further delay sealing. If any of the strips have not activated properly after a
reasonable time period, hand sealing may be necessary. Shingles in prolonged storage may pick up
temporary staining, which is removed by natural weathering. Double stacking can cause staining
and sticking in the bundle. Atlas Roofing Corporation also endorses the Asphalt Roofing
Manufacturers Association’s (ARMA) recommendations for application details not specified on this
wrapper.
2. ROOF DECK VENTILATION
Adequate ventilation under the roof deck must be provided to prevent harmful condensation in
winter and heat build-up in summer. These conditions can cause:
A. Accelerated shingle weathering B. Deck rot and attic fungus C. Shingle distortion/cracking due to
deck movement D. Cosmetic blisters on the shingle surface.