4. Input 3
Input3consistsofstereosumminginputs,suitableforconnectiontotheoutputofCD/DVDplayers,etc.
5. Mute Sensitivity Control
VOXMuteSensitivityControladjustshowsensitivethemutesendcircuitryonInput1reacts.Settingthecontrolfullycounter-
clockwise will lower the sensitivity, where a higher amplitude signal will be required at Input 1 to trigger the mute send circuits.
Fully clockwise will raise the sensitivity of the mute circuits, where a lower amplitude signal will trigger a mute send. Careful
calibrationofthiscontrolmayberequiredtofullyutilizethecapabilitiesofthemutecircuits.
6. 70.7V / 100V Speaker Connections
For loudspeaker connections, follow the labeling paying special attention to the polarity or proceed to the Limit LED & Load
Considerationssection.Note:Donotshorttheterminalstogetherordamagemayoccur.
7. Global IEC AC Mains Power Receptacle
TheMAModelssupportglobalpowersourcesfrom100V-240V50/60Hz.Thepackagecontainsacordthathasaninternational
IECconnectortoa120VUSAtypeplug.ItmaybenecessarytoreplacetheremovablepowercordtomeetyourACmainsplug
typeusedinyourcountry.Note:ItisnotrequiredtochangethefuseforthedifferentACmainsvoltages.
8. Remote Mute Connector
Shorting the Remote Mute terminals will mute inputs 2 and/or 3, depending on how their dipswitch settings are set for switch
positions1and2labeled"MuteRec"/"Input2"&"Input3".Inthe"ON" position, the corresponding channel will be muted when
the terminals are shorted together. This connection is usually done via remote switch on a microphone.
Wiring the MA40G/MA60G
SpeakerOutputs-Use2conductorunshieldedwireoftheappropriategauge.Ifyouareunsureaboutthis,contactAtlasSoundTech
Supportat1-800-876-3333.Makesureyouknowhowmanyspeakersyouneedandwhattapvalueyouintendtouse.
Mic/LineInput-2conductorwithshieldforlowlevelsignalsof20-22-gaugeisbest.Maintaintheproperpolarity,+to+,–to–,and
shield to ground.
UnbalancedInputsandOutputs-Pre-madeRCAcablescanbepurchasedfromvendorstosimplifyinterconnectiontoexternaldevices.
Security Cover Option
InordertopreventunauthorizedoperationoftheMA40G&MA60G,optionalsecuritycoversareavailablewhichtaketheplaceofthe
front panel knobs. After the MA amplifier has been installed and is operating as desired, grasp the front panel knobs and pull straight out
fromthefrontpanel.Replacetheknobswithsecuritycovers,AtlasSoundpartnumberMPVCC-5,availableinquantitiesof5.
Rack Mount Kit Option
The MA40G & MA60G can be rack mounted as a single unit or with two units together. To do so a PA702RMK Rack Mount Kit needs to
be purchased from Atlas Sound.
Front Panel Knob Security Cover
or
Front Panel Knob Security Cover
or