Limit LED and Load Consideration
If the Red Limit LED illuminates, the amplifier has sensed an improper load or the input signal is too high, triggering the protection
circuitry. When the load sense Limit circuitry is engaged the amp will operate but at a lower power output. It is s highly recommended
to discontinue use immediately and correct the fault condition. If you continue to operate with the RED Limit LED on, the second stage
of the current sense circuit may engage causing the amp not to pass any signal. To reset the amp turn down the Level controls and turn
the power off for 10 seconds.
In most situations when the Limit LED is in the illuminated steady state it means the speaker system load to the amp is lower than
whattheampisrated.Thisusuallyisdetectedwhenthesystemisfirstsetup.Belowareafewloadconditionstocheckforifthe
Limit LED is on.
1. Connectedtothewrongspeakerterminal.Alwayscheckthespeakerterminaltothetypeofloadyouareusing.Example:If
youareinstallinga70Vor100Vsystemmakesurethewiresareconnectedtothe70V/100Vandcommon(COM)terminals.
2. Toomanyspeakersconnectedtotheamp.Thisisaverycommonmistake.Ifyouareusinga60Wampandusingthe70V
speaker terminals, add up the number of speakers and their wattage selections at the speaker. If they exceed 60W you must
retap the speakers or remove the correct amount of speaker wattage until the wattage is 60W or less. Example if you are
using a 30W tap you can only connect 2 speakers to the amp. If you are using the 7.5W tap, you can connect 8 speakers. If
you have too many speakers on the amp it will load the amp down, causing excessive current demand and will trigger the
Limit & Protect circuit.
3. Wrongspeakertapselection.Itisalsocommonina70Vor100Vsystemthatoneofthespeakersissetattoolowofan
impedance(8ohm)andnota70vor100vtap.Note:Itonlytakesonespeakertoloadtheampdownincorrectly.
4. Short in system. This is common if the wire is run in metal conduit and the wire got nicked during the wire pull.
5. SpeakerLevelControls.IfanL-PADorsteppedattenuatoriswiredwrongitcanalsoloadasystemdown.
Measuring Speaker Loads
BelowisanImpedanceloadchartfortheMA40GandMA60G.Measuretheloadimpedancepriortoconnectingtheloadtothe
amplifier. The enclosed load chart will provide the information to determine if the load or speaker system impedance is too low for the
amplifier's rating. In every install it is always recommended to measure the load prior to turning the system on to be sure the system
is installed correctly.
MA40G & MA60G Max Load Chart
Speaker
Selection
MA40G
MA60G
70.7V
100V
125 Ohms
166 Ohms
250 Ohms
83 Ohms