CAUSE
No traction.
Air leaks from the engine (M), with
air on (4) and (3).
Pressing the trigger you start the
piston traction, but the piston return
is slower or absent; air leaks from
the mufer (6).
SOLUTION
Tool needs oil.
Remove the engine cover (M), remove the bottom (1) and check
that hole Ø 0.8 is open.
Remove the engine cover (M): a substantial leak of air means that
o-ring Ø 30 (4) is broken. If only a small quantity of air comes out of
the small tubes (5) you have to replace the o-rings.
If air leaks from the two holes (2) make sure that o-rings are not
broken or worn.
If there are no leaks from the engine (M), you must check the
lubrication, greasing the o-rings (3) and (4).
Make sure that you have all the above components, clean the
mufer (6) with air, grease and reassemble everything. In case
cleaning do does not work, you need to replace the mufer (6). If air
still leaks, replace the o-ring (7).