Owner's Manual

– 21 –
AZA Series
Owner’s Manual
AtlasIED.com
TELEPHONE: (800) 876-3333
SUPPORT@ATLASIED.COM
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
AC Power Requirements
Operating Voltage 110V - 120V & 220V - 230V 50/60Hz, Auto Voltage Sense
Mains Interface IEC 15A Receptacle
Power Cord (Included) 1.5m, IEC C13 to NEMA 5-15P Plug, 18AWG
Minimum Power-Up Voltage 90V
Maximum Operating Voltage 264V
Recommended AC Mains Current Requirements
AZA404: 2.7A (Speech & Background Music), 8.2A (Max Usage)
AZA804: 5.3A (Speech & Background Music), 15A (Max Usage)
AZA404
Power Consumption / Current Draw (Note 5)
Amps
Watts
BTU / hr (Note 4)
Sleep Mode 90mA 4W 12 BTU
Standby / APD Mode (Note 2) 225mA 18W 56 BTU
Idle Active Mode (Note 2) 650mA 40W 126 BTU
Average Power 4Ω, All Channels Driven (Note 3) 2.2A 160W 504 BTU
Average Power 70V, All Channels Driven (Note 3) 2.7A 215W 648 BTU
Max Power 4Ω, All Channels Driven (Note 4) 6.1A 486W 1479 BTU
Max Power 70V, All Channels Driven (Note 4) 8.2A 710W 2079 BTU
AZA804
Power Consumption / Current Draw (Note 5)
Amps
Watts
BTU / hr (Note 4)
Sleep Mode 90mA 4W 12 BTU
Standby / APD Mode (Note 2) 225mA 18W 56 BTU
Idle Active Mode (Note 2) 650mA 40W 126 BTU
Average Power 4Ω, All Channels Driven (Note 3) 3.7A 270W 964 BTU
Average Power 70V, All Channels Driven (Note 3) 5.3A 425W 1280 BTU
Max Power 4Ω, All Channels Driven (Note 4) 9.5A 794W 2369 BTU
Max Power 70V, All Channels Driven (Note 4) 15.9A 1362W 3692 BTU
Dimensions and Weight
Rack Mount Requirements 1 RU, 19"
Dimensions - Unit W 19" x H 1.77" x D 15.5" (483mm x 45mm x 394mm)
Dimensions - Shipping W 24.5" x H 3.5" x D 18.7" (635mm x 89mm x 477mm)
Weight - Unit 13 lbs. (5.92kg)
Weight - Shipping 17.4 lbs (7.94kg)
Agency Approvals
North America Agency TUV
Testing Standard North America 60065
FCC Class A (Conducted & Radiated Emissions) Part 15 of the FCC Rules
RoHS / WEEE Compliant Ye s
CE Ye s
Optional Accessories
AZA IP Discovery Software Ye s
DPA-DAC4 4 CH Dante™ Receiver
DPA-AMIX (2) Mic / Line, (2) AUX Input Card
Notes:
1. Power level measurement is defined as follows: 1KHz Sine wave signal burst of 20 cycles (20mS) at 1% THD+N, followed by 480 cycles of a 1kHz
sine wave at 10% of the max power. Other power measurements are available upon requests.
2. Power measurement with Ethernet connected. Without Ethernet connected deduct 0.2W
3. Average Power is defined as Pink Noise input signal applied to achieve
1
/4 of the 4 Ohm or 70.7V power rating.
4. Max Power is defined as 1 KHz input signal applied to achieve the maximum power output before clipping into a 4 Ohm or 70.7V load.
5. BTU is calculated by the AC Mains Power consumed minus the total power output measured at the specified load and condition, multiplied by
3.412. Example: 785 Watts from the AC Source - 600 Watts Total Output power = 185 x 3.412 = 631 BTU