Owner's Manual

– 22 –
AZA Series
Owner’s Manual
AtlasIED.com
TELEPHONE: (800) 876-3333
SUPPORT@ATLASIED.COM
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
Dimensional Drawings
1
Signal
Channel
Limit/
Protect
4/8Ω
70/100V
2 3 4
Ch. 1/2 3/4
Operating Mode
AZA404
Amplifier
Channel
Outputs
Class 3 Wiring
Fuse
T4A L 250V
110-120V/220-240V~50/60Hz 4A
1
+
1
2
+
2
3
+
3
4
+
4
CH 1 CH 2 CH 3 CH 4
Amplifier
Accessory Card Slot
Ethernet
Configuration Interface
Web Browser Access
Input [1] [4] Input[2] [3]
G
+
G
+
G
+
G
+
For AZA Configuration Instructions
Visit www.AtlasIED.com/AZA-Series
+10V C2
Control Ports
C1 C3
C4
GND
Note: Amplifier output load configuration is set via DSP GUI
Factory Reset Instructions
To reset IP configuration to factory default settings:
• Disconnect the power from the device
• Wait 60 seconds
• Connect power to the device
• Press and hold front panel power switch until LED blinks 5 times quickly
• IP configuration is reset to factory default settings
• Factory settings DHCP enabled
• For direct connection to amp refer to installation guide
1601 Jack McKay Blvd. • Ennis, TX 75119
800.876.3333 • AtlasIED.com
WARNING: SHOCK HAZARD - DO NOT OPEN
AVIS: RISQUE DE CHOC ELÉCTRIQUE - NE PAS OUVRIR
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK
DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE
AVIS: NE PAS EXPOSER CE MATÉRIEL À LA PLUIE OU L’HUMIDITE
AFIN DE REDUIRE LE RISQUE D’INFLAMMATION OU DE CHOC ELÉCTRIQUE
CAUTION: For continued protection
against risk of fire, replace only with
same type fuse and rating.
ATTENTION: Utiliser un fusible de
rechange de meme type et calibre.
FUSE RATING:
AZA404 - T4A L 250VAC
110-120V/220-240V~50/60Hz 4A
AZA804 - T8A L 250VAC
110-120V/220-240V~50/60Hz 8A
Note: Out of the box, the AZA Amplifier
is configured in 70 Volt mode.
Certified to IEC 62368-1
1.72"
(43.7mm)
19"
(480.8mm)
14"
(355.6mm)
1"
(25.4mm)
17"
(431.8mm)
1
Signal
Channel
Limit/
Protect
4/8Ω
70/100V
2 3 4
Ch. 1/2 3/4
Operating Mode
AZA404
Amplifier
Channel
Outputs
Class 3 Wiring
Fuse
T4A L 250V
110-120V/220-240V~50/60Hz 4A
1
+
1
2
+
2
3
+
3
4
+
4
CH 1 CH 2 CH 3 CH 4
Amplifier
Accessory Card Slot
Ethernet
Configuration Interface
Web Browser Access
Input [1] [4] Input[2] [3]
G
+
G
+
G
+
G
+
For AZA Configuration Instructions
Visit www.AtlasIED.com/AZA-Series
+10V C2
Control Ports
C1 C3
C4
GND
Note: Amplifier output load configuration is set via DSP GUI
Factory Reset Instructions
To reset IP configuration to factory default settings:
• Disconnect the power from the device
Wait 60 seconds
• Connect power to the device
• Press and hold front panel power switch until LED blinks 5 times quickly
• IP configuration is reset to factory default settings
• Factory settings DHCP enabled
• For direct connection to amp refer to installation guide
1601 Jack McKay Blvd. • Ennis, TX 75119
800.876.3333 • AtlasIED.com
WARNING: SHOCK HAZARD - DO NOT OPEN
AVIS: RISQUE DE CHOC ELÉCTRIQUE - NE PAS OUVRIR
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK
DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE
AVIS: NE PAS EXPOSER CE MATÉRIEL À LA PLUIE OU L’HUMIDITE
AFIN DE REDUIRE LE RISQUE D’INFLAMMATION OU DE CHOC ELÉCTRIQUE
CAUTION: For continued protection
against risk of fire, replace only with
same type fuse and rating.
ATTENTION: Utiliser un fusible de
rechange de meme type et calibre.
FUSE RATING:
AZA404 - T4A L 250VAC
110-120V/220-240V~50/60Hz 4A
AZA804 - T8A L 250VAC
110-120V/220-240V~50/60Hz 8A
Note: Out of the box, the AZA Amplifier
is configured in 70 Volt mode.
Certified to IEC 62368-1
1.72"
(43.7mm)
19"
(480.8mm)
14"
(355.6mm)
1"
(25.4mm)
17"
(431.8mm)