Owner's Manual

1. Using a measuring device, mark off 12.25" from one end of tile.
2. Carefully cut tile on mark using utility knife, drywall saw, or RotoZip
TM
.
3. Remove E.O. box cover (A) on enclosure.
4. Use two wire nuts (included) to attach the red (+) and black (-) leads to the field
wiring.
5. Set tap selector switch (B) for desired power.
6. Install DT12 into the grid with the unit’s tile support edge facing out from the
installation location. If the speaker location is not favorable, the tile support
edge may be moved to the other side of the DT12.
7. Replace the cut section of acoustic tile.
Power Settings 25V / 70.7V: .25, .5, 1, 2, 4 watts and 8ȍ
Frequency Response: 85 Hz - 8 kHz
Sensitivity: 97 dB (1 W / 1 M)
NOTE: Wiring cavity is not intended to be used as a junction box.
A UL recognized conduit clamp must be used for conduit connections.
Installation must comply with all Building
Codes and NFPA guidelines.
Installation must adhere to N.E.C. and
NFPA 70/72 wiring directives
and comply with all National and
Local Building Codes.
Input
DT12
Full Range
4 Watts @ 70.7V
DT12
Full Range
4 Watts @ 70.7V
DT12
Full Range
4 Watts @ 70.7V
DT12
Full Range
4 Watts @ 70.7V
Typical Parallel Hookup of Full
Range 70.7 / 100V Speakers
Amplifier
Typical 120 Watt 70.7V Output
Tap Wattage Total: 16 Watts
AtlasSound.com
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
Specifications are subject to change without notice.
©2008 Atlas Sound ATS003230 RevA 8/08
TELEPHONE: (800) 876-3333
FAX (800) 765-3435
Installation Sheet for DT12
Acoustic Tile

Summary of content (4 pages)