Owner's Manual
10
Installation Guide
AT-HDR-EX-100CEA-KIT
1. Launch the Analyzer software.
2. Set the UTILITY dial to 3.
3. Connect a mini-USB to USB-A cable from the UTILITY port, on the transmitter, to a
computer.
4. Select the COM port and press the Connect button.
5. Click Debug on the menu bar.
6. The debug process will begin and any debug data
will be logged in the text box.
7. Click the Save Log button to save the data to a
le on the computer or click the Clear button to
erase the data in the text box.
8. Once the debug process is complete, set the
UTILITY dial to 1 to resume normal operation.
Debugging
4. 5V LOCK
This mode sets both the HPD pin on the transmitter and the +5V pin on the receiver to “high”.
This allows both the source and display to have a consistent connection, even if there are issues
with the source and / or display signals.