Owner's Manual

9
Installation Guide
AT-HDR-EX-100CEA-KIT
1. LINK
This is the default position. Make sure that the dial is set to the LINK position for normal
operation.
2. FW
This mode sets the transmitter to rmware update mode. Refer to Updating the Firmware (page
11) for more information.
1. Launch the Analyzer software.
2. Make sure the system is powered and the transmitter and receiver are connected using the
HDBaseT OUT and HDBaseT IN ports.
3. Connect an active source to the transmitter and an active display to the receiver. Set the
source to the highest resolution.
4. Set the UTILITY dial to 3.
5. Connect a mini-USB to USB-A cable from the UTILITY port, on the transmitter, to a
computer.
6. Select the COM port in the Analyzer software and press the Connect button.
7. Click Quality on the menu bar.
8. Once connected, press the Start button. The link information and cable pairing test results
will display. Follow the instructions on the Analyzer software for any pair failures.
9. When complete, set the UTILITY dial back to 1 to resume normal operation.
3. TEST
This mode sets the transmitter to HDBaseT testing and debug mode. The TEST mode works
in conjunction with the Atlona Analyzer. This software is free and is available from http://www.
atlona.com/products/AT-HDR-EX-100CEA-KIT.
HDBaseT Testing
Utility Switch
The UTILITY port and dial are used for updating rmware, HDBaseT cable testing/debugging,
and 5V lock. Use the dial to switch between modes.
LAN
HDMI OUTHDBaseT IN
TX TX RXRX P
IRRS-232
IN
OPTICAL
DC 48V HDMI IN LANHDBaseT OUTOPTICAL
TX TX RXRX
-
+
OUT
IRRS-232
POWER
LINKTEST
AT-HDR-EX-100CEA-TX
1. LINK
2. FW
3. TEST
4. 5V LOCK
UTILITY
POWER
LINK
AT-HDR-EX-100CEA-RX
FW
UTILITY dial
UTILITY port