Connection Instructions
1. Connect an Ethernet cable from the ETHERNET port on the decoder to a PoE-capable switch on the Local Area
Network (LAN). If using the dual-channel decoder, connect a separate Ethernet cables to ETHERNET 1 and
ETHERNET 2 ports.
2. Connect an HDMI cable from the HDMI OUT port on the decoder to a display. If using the dual-channel
decoder, connect an HDMI cable from each HDMI OUT port to a display.
3. RS-232 (optional)
Connect the RS-232 controller/automation system to the RS-232 port on the decoder.
Connect the RS-232 device to the RS-232 port on the decoder.
4. External Audio (optional)
Connect the audio inputs to the decoder, as required.
Connect the audio outputs to the decoder, as required.
5. IR (optional)
IR emitter
Connect the IR emitter to the TX and GND pins of the RS-232 2 port. The IR emitter must be placed no
more than 1” from the IR sensor on the device, in order to function properly.
IR extender
Connect the IR extender from the RX and GND pins of the RS-232 2 port to the associated pins on the
control system.
6. Once power is applied, the PWR indicator, on the front panel, will turn red, then amber, then green.
IMPORTANT: If a PoE-capable switch is not available, then the 48V DC power supply (sold
separately) must be connected to the decoder.
Installation
IMPORTANT: When using analog audio inputs on the OmniStream decoder, the decoder must be
powered using the 48V power supply (AT-PS-48083-C). This power supply is sold separately and
can be purchased from Atlona.
NOTE: For dual-channel decoders, only the RS-232 2 port supports both serial and IR. Single-
channel decoders only support IR on the RS-232 2 port. The IR emitter or IR receiver must always