AT-OMNI-121 / AT-OMNI-122
40
IR Control
Conguring the Encoder Serial Port
The rst step will be to congure the RS-232 port on the encoder to use IR. Only the RS-232 2 port supports both
RS-232 and IR. Therefore, this port must be used for IR. RS-232 port conguration is managed under the Serial
page of the encoder web interface.
1. Enter the IP address of the encoder in the address bar of the web browser.
2. Enter the required login credentials. The default login is:
Username: admin
Password: Atlona
3. Click the Login button.
4. Click Serial in the top menu bar.
SAVE button
5. Locate the Serial port conguration window group. The Name eld, within this window group, should read
serial_port2. Click the Mode drop-down list and select Infrared.
6. Click the SAVE button to commit changes.