User Manual

Table Of Contents
AT-OMNI-121 / AT-OMNI-122
43
IR Control
Conguring the Decoder Serial Port
1. Select the desired decoder within the AMS Device List window and make note of the decoder IP address.
2. Enter the required login credentials. The default login is:
Username: admin
Password: Atlona
3. Click the Login button, then click IP Input in the top menu bar.
4. Scroll down to the Input 5 window group.
5. Enable Input 5 by clicking the Enable toggle switch. When enabled, this toggle switch will be orange.
6. Enter the port in the Port eld. This port number must be the same port used by the encoder, and is the input of
the decoder that will receive IR data.
NOTE: Input 5 is dedicated to IR. Therefore, this input must be used in order for end-to-end IR to
function properly.
Enable
SAVE button
IMPORTANT: Do not change the contents of the Multicast Address eld. Unicast mode uses the
IP address of the decoder for communication. Therefore, only the port number is required.
7. Click the SAVE button to commit changes.