Warranty

Technical Information
Model Guide - kW Output
2
Model *Wattage Voltage Amperage Phase
Circuit breaker
size
Required wire
size
AT-800-35 3.0 kW 110 27 1 30 10 AWG
AT-800-04 3.8 kW 240 16 1 20 12 AWG
AT-800-70 7.0 kW 240 29 1 30 10 AWG
AT-800-08 8.5 kW 240 36 1 40 8 AWG
AT-800-10 10.5 kW 240 44 1 50 6 AWG
AT-800-13 13 kW 240 55 1 60 4 AWG
Minimum water ow to activate unit: 0.5 GPM
Nominal water volume: 2.7G/Min
Working pressure: 0.5 -8 bar (7 -115 psi)
Tested pressure: 16 bar (230 psi)
Water connections: 1/2" NPT
Dimensions (in) (H x W x D): 7.3 x 11.8 x 3.55
Weight (Ib): 3.4
Model 240V 220V 110V 120V
AT-800-04 3.8 kW 3.2 kW - -
AT-800-70 7.0 kW 5.4 kW - -
AT-800-08 8.5 kW 7.1 kW - -
AT-800-10 10.5 kW 8.8 kW - -
AT-800-13 13.0 kW 10.9 kW - -
AT-800-35 - - 3.0 kW 3.5 kW
* Wattage based on maximum voltage.