User's Manual

18 19
If the cable size is 12 AWG, you should use a 12 V power supply. And the
distance between the power supply and the device should be no more
than 40 m.
4.1. TERMINAL DESCRIPTION
The terminals contains power input, alarm input, alarm output, RS-485, Wie-
gand output, and door lock.
The terminal’s diagram is as follows:
Figure 4-1. Terminal Diagram
The descriptions of the terminals are as follows:
Table 4-1. Terminal Descriptions
Group No. Function Color Name Description
Group A
A1
Power Input
Red +12 V 12 VDC Power Supply
A2 Black GND Ground
Group B
B1
Alarm Input
Yellow/Blue IN1 Alarm Input 1
B2 Yellow/Black GND Ground
B3 Yellow/Orange IN2 Alarm Input 2
B4
Alarm Output
Yellow/Purple NC Alarm Output
B5 Yellow/Brown COM
Wiring
B6 Yellow/Red NO
Group C
C1
RS-485
Yellow 485+ RS-485 Wiring
C2
Blue
485-
C3 Black GND Ground
C4
Wiegand
Green W0 Wiegand Wiring 0
C5 White W1 Wiegand Wiring 1
C6 Brown WG_OK Wiegand Authenticated
C7 Orange WG_ERR Wiegand Authentication Failed
C8 Purple BUZZER Buzzer Wiring
C9 Gray TAMPER Tampering Alarm Wiring
Group D
D1
Door Lock
White/Purple NC Lock Wiring (NC)
D2 White/Yellow COM Common
D3 White/Red NO Lock Wiring (NO)
D4 Yellow/Green SENSOR Door Contact
D5 Yellow/Gray BTN Exit Door Wiring
4.2. WIRE NORMAL DEVICE
You can connect the terminal with normal peripherals.
Follow the diagram below to wire the thermographic module and the device
main body:
The wiring diagram without secure door control unit is as follows.