User's Manual

46 47
Figure 6-13. Access Control Parameters
The available parameters descriptions are as follows:
Table 6-4. Access Control Parameters Descriptions
Parameter Description
Terminal Auth.
Mode
Select the face recognition terminal’s authentication mode.
You can also customize the authentication mode.
NOTE
Biometric recognition products are not 100% applica-
ble to anti-spoofing environments. If you require a higher
security level, use multiple authentication modes.
If you adopt multiple authentication modes, you should
authenticate other methods before authenticating face.
Reader Auth. Mode Select the card reader's authentication mode.
QR code
You can use the QR code scanning function on the authenti-
cation interface. The device will upload the information asso-
ciated with the obtained QR code to the platform.
Remote
Authentication
When you authenticate the permission, the platform will
control whether to grant the access or not remotely.
Door Contact
You can select Open or Closed according to your actual
needs. By default, it is closed.
Door Locked Time
Set the door unlocking duration. If the door is not opened for
the set time, the door will be locked. Available door locked
time range: 1 to 255 s.
6.10. MAINTENANCE
6.10.1. Upgrade Firmware
Plug in the USB flash drive. Tap Maint. (Maintenance) on the System Set-
tings page and tap Upgrade. The device will automatically read the upgrading
file in the USB flash drive and upgrade the firmware.
The device can also be upgraded by unplugging the device, plugging in
USB, and rebooting. The upgrade will occur automatically.
NOTE
Do not power off during the device upgrade.
The upgrading file should be in the root directory.
The upgrading file name should be digicap.dav.
Figure 6-14. Upgrade
6.10.2. Data Management
On the Data Management page, you can delete user data, restore to factory
settings, or restore to default settings.
Tap Data (Data Management) to enter the Data Management page. Tap the
button on the page to manage the data. Tap Yes on the pop-up window to com-
plete the settings.
The available button descriptions are as follows:
Table 6-5. Data Descriptions
Parameter Description
Delete User Data Delete all user data in the device.
Restore to Factory
Restore the system to the factory settings. The device will
reboot after the setting.
Restore to Default
Restore the system to the default settings. The system
will save the communication settings and the remote user
settings. Other parameters will be restored to default. The