User's Manual

82 83
Figure 7-7. Remotely Open Door
NOTE
You can check Offline Authentication to enable the super password au -
thentication when the access control device is disconnected with the client.
Local Authentication and Super Password
Authentication by the access control device and by the super password.
d) Select the added person/card group in the left list below and it will be
added to the Selected list on the right as the authentication group.
e) Click the added authentication group in the right list to set authentica-
tion times in the Auth Times column.
NOTE
The authentication times should be larger than 0 and smaller than the
added personnel quantity in the personnel group.
The maximum value of authentication times is 16.
f) Click Save.
NOTE
For each access control point (door), up to four authentication groups
can be added.
For the authentication group of which authentication type is Local
Authentication, up to 8 person/card groups can be added to the authen-
tication group.
For the authentication group of which authentication type is Local
Authentication and Super Password or Local Authentication and
Remotely Open Door, up to 7 person/card groups can be added to the
authentication group.
7. Click Save.
7.6.3. Configure First Person In
You can set multiple first persons for one access control point. After the first
person is authorized, it allows multiple persons access the door or other au-
thentication actions.
Before You Start
Set the access group and apply the access group to the access control de-
vice. For details, refer to Set Access Group to Assign Access Authorization to
Persons.
Perform this task when you want to configure opening door with first person.
Steps
1. Click Access Control Advanced Function First Person In to enter the
First Person In page.
2. Select an access control device in the list on the left panel.
3. Select the current mode as Enable Remaining Open after First Person
or Disable Remaining Open after First Person from the drop-down list for
each access control point of the selected device.
Enable Remaining Open after First Person
The door remains open for the configured time duration after the first person
is authorized until the remain open duration ends. If you select this mode, you
should set the remain open duration.
NOTE
The remain open duration should be between 0 and 1440 minutes. By
default, the remain open duration is 10 minutes.
Disable Remaining Open after First Person
Disable the function of first person in, namely normal authentication.
NOTE
You can authenticate by the first person again to disable the first person
mode.
4. Click Add on the First Person List panel.
5. Select person(s) in the left list and the person(s) will be add to the select-
ed persons as the first person(s) of the doors.
The added first person(s) will list in the First Person List
6. Optional: Select a first person from the list and click Delete to remove the
person from the First person list.
7. Click Save.
7.6.4. Configure Anti-Passback
You can set to only pass the access control point according to the speci-
fied path and only one person could pass the access control point after swip-
ing the card.
Before You Start
Enable the anti-passing back function of the access control device.
Perform this task when you want to configure the anti-passing back for the
access control device.
Steps
NOTE
Either the anti-passing back or multi-door interlocking function can be
configured for an access control device at the same time. For the config-
uration of multi-door interlocking, refer to.
Click Access Control Advanced Function Anti-Passback to enter the
Anti-Passpack Settings page.
1. Select an access control device on the left panel.