User's Manual

User manual Version 1.0
ABLELink
Serial-Ethernet Server
GW51W-MAXI
Copyright © 2003 Atop Technologies, Inc.
All rights reserved. Designed in Taiwan.
33 / 54
4.5.2.2 Run Serial/IP for ATOP program on monitoring PC
In the Window Start Menu, select the Serial/IP for ATOP program group and select Serial/IP for
ATOP Configuration. The configuration window is shown as following:
At right is a sample Virtual COM Control Panel window. At the left is the list of the COM ports that
you have selected (in the Select Ports window) for use by the Virtual COM Redirector. If you wish to
change which ports appear in this list, use the Select Ports button.
Each COM port has its own settings. When you click on a COM port, the Control Panel display
changes to reflect the settings for that COM port.
Note: When you change settings for a COM port, the changes are effective immediately. There is
no separate confirmation dialog to confirm or cancel your changes.
Configuring Virtual COM Ports
You configure each Serial/IP COM port as follows:
1. Select a COM port in the list.
2. For IP Address of Server, enter a numeric IP address for the serial server.
3. For Port Number, enter the TCP port number that the serial server uses to provide its
serial ports to the network.
4. For Server Credentials, the default is No Login Required. If your serial server does
require a login by the Virtual COM Redirector, the Virtual COM Redirector needs to provide
a username and/or password every time an application tries to use the serial server.
5. Click the Configuration Wizard button and then click the Start button that appears in the
wizard window. This important step verifies that the Virtual COM Redirector can
communicate with the serial server using the settings you have provided. If the Log display
does not show errors, click the Use Settings button in the wizard, which makes the