User's Manual

User manual Version 1.0
ABLELink
Serial-Ethernet Server
GW51W-MAXI
Copyright © 2003 Atop Technologies, Inc.
All rights reserved. Designed in Taiwan.
49 / 54
B.2 Critical Issues of Upgrading
1. You can always abort the upgrading process by pressing the <Esc> key from host PC during the
upgrading process. GW51W-MAXI will restart automatically and the system remains intact.
2. If GW51W-MAXI does not receive any upgrading data within 30 seconds, GW51W-MAXI will restart
automatically and the system remains intact.
3. After the upgrading process finishes, GW51W-MAXI will program the flash memory and buzzer beeps
6 times then restarts. Normally, it takes around 10 seconds to complete the programming process. If
an error occurs during the programming process, GW51W-MAXI will clear the corresponding memory
and the system remains intact of what it was.
B.3 Error Messages
Firmware upgrade may not be successful if errors occur during the process.
Error Cause
Message
Comments
Illegal Hex file format
Hex File Text Error
Hex File Check-Sum Error
Hex File Format Error
Hex File End of Record Error
GW51W-MAXI handshaking problem
GW51W-MAXI ACK Start Address Error
GW51W-MAXI ACK Length Error
GW51W-MAXI Response Command Error
Configuration file
Remote IP not found
Open configuration file failure