User Manual
User Manual Version 1.6
SE5001 Serial Device Server
Copyright © 2011 Atop Technologies, Inc.
All rights reserved. Designed in Taiwan.
20
3. If IP filter is enabled, only source IP assigned can connect to SE5001’s COM.
4. If the multi-connection firmware is installed, SE5001 will prompt for “Multi_Port”, meaning multiple
connection
3.2.6. Configure SE5001 as TCP Client
Figure 3.11 Link Mode: TCP Client Setup
Type 2 in the “Input choice(1~5) and enter:“
Input destination IP in the “Please input Destination IP:”
Input destination port in the “Please input Destination port:”
Select TCP connection behavior: 1 for connect always, 2 for connect on serial data
If 2 is selected, console will prompt for additional configurations.
Input idle time to disconnect in the “Please input idle time to disconnect(0sec , 1~255):” (Input 0 to
disable; Input 2 to disconnect TCP connection after 2 seconds of serial Inactivity)
Input error retrying time in “Please input waiting time for error retrying(0 minute,1~255):” (Input 0 to
disable; Input 2 to try to connect to a TCP Server every 2 minutes)
Input idle time in “Please input idle time to send TCP alive packet(x*10sec):”(Input 2 to the send TCP
keep alive packet every 20 seconds)