B.2 Critical Issues
1. The upgrading process can be aborted by pressing the <Esc> key. SE5002 will restart automatically and
the system remains the same.
2. If SE5002 does not receive any upgrading data within 30 seconds, it will restart automatically and the
system remains the same.
3. After the upgrading process is done, SE5002 will program the flash memory, and the buzzer beeps 6
times before restarting. It takes around 10 seconds to complete the programming process. If an error
occurs during the programming process, SE5002 will clear the corresponding memory and the system
remains the same before the process.
B.3 Error Messages
Firmware upgrade may not be successful if errors occur during the process.
Error Cause Message Comments
Illegal Hex file format Hex File Text Error
Hex File Check-Sum Error
Hex File Format Error
Hex File End of Record Error
SE5002
handshaking problem
SE5002 ACK Start Address Error
SE5002 ACK Length Error
SE5002 Response Command Error
Configuration file Remote IP not found
Open configuration file failure