User manual Manual

Industrial Wireless Serial Device Server Series
SW550xC User Manual V 1.0
67
5.2.8 UDP Application: Multi-Point Pair Connection
It is also possible to setup pair connection in UDP mode to have more than one Pair
Connection Master or Slave to communicate to each other. For example, it is possible to setup
one Modbus Master and six Modbus Slaves in UDP, Figure 5.16. Note again that UDP does
not guarantee data delivery and only data would be transmitted over Ethernet; other serial
pings are not transmited. If RS-232 along with flow control, it is recommended to use
Multi-Point Pair Connection in TCP, see Sec.TCP Server Application: Multi-Point TCP Pair
Connections.
Note: the destination IP and Port of the Slaves need to be equal to the Master’s IP and Port. Local Listening Port of
the Slaves need to be equal to the Master’s Destination Port, see Table for an example.
Table 5.1
IP Address
Link Mode
Local Listening
Port
Destination IP
Destination
Port
SW5501C Master
COM1
10.0.50.100
UDP
5000
10.0.50.200~10.0.50.203
5000
SW5501C Master
COM1
10.0.50.100
UDP
5001
10.0.50.200~10.0.50.201
5001
SW5502C Slave 1
COM1
10.0.50.200
UDP
5000
10.0.50.100
5000
SW5502C Slave 1
COM2
10.0.50.200
UDP
5001
10.0.50.100
5001
SW5502C Slave 2
COM1
10.0.50.201
UDP
5000
10.0.50.100
5000
SW5502C Slave 2
COM2
10.0.50.201
UDP
5001
10.0.50.100
5001
SW5501C Slave 3
COM1
10.0.50.202
UDP
5000
10.0.50.100
5000
SW5501C Slave 4
COM1
10.0.50.203
UDP
5000
10.0.50.100
5000