User's Manual

Atop Wireless coordinator
ATW330-4X
User Manual V. 1.0
22
Item
Description
COM
Extend RS-485 port (Reserved).
Proprietary protocol.
Connector: Terminal Block/Male/5.08mm pitch/4pins.
Pin Assign: NC/D+/D-/G
LED indication
PWR: Power Indicator x 1
RUN: System Status Indicator x 1
Tx/Rx: Between Host & Device Communication x 2.
RF: Wireless status Indicator x 1.
LAN Indicator: Link & Speed Indicator x 2.
Reset/Default
Reset: Hold 3sec to Reboot device.
Default: 6sec Reset to Factory Default & reboot.
Buzzer
Build in Buzzer beeper.
Power
Requirement
Input:
Voltage: DC +12VDC +/- 10% Max.
Current: 1.0A max. @ 12VDC.
Connector Type:
1. DC-JACK (Inner V+, 2.1mm).
2. Terminal block (V+/V-/F.G.; Pitch:5.08mm /3pins/Male).
Case Shielding Ground: M4 + Screwing.
PoE IEEE802.af PD (optional for ATW330-42)
Protection:
1. Inrush Current Protection.
2. Power Voltage Reverse Protection.
Operation
Temperature
Operation: 0 to 50C (32 to 122F)
Storage: -20 to 60C (-4 to 140F)
Ambient Humidity
Operation & Storage: 5 ~ 90% (non-condensing).
Housing
Size: 148mm x 125mm x 33mm ( 5.83 x 4.92 x 1.30 in).
Material: Metal Case.
Weight: ATW330-41:0.44Kg
ATW330-42:0.45Kg