Owner`s manual

11
139435_A GZ 455 DV 8/28/12
Noncombustible
Material
Finished Floor may be
combustible material
Install cabinet on min. 1 in. riser
to accommodate optional
Backer Plate
Figure 4.10.
Wall materials with Backer Plate installation, cut-away view.
Figure 4.11.
Wall materials without Backer Plate, cut-away view.
Raisedsupportplatformmaybe
combustible material.
Face Plate
37” x 23” (94cmx58.4cm)
CombustibleWallFacing
Backer Plate
43”x303/8” (109.2 cm x 77.1 cm)
Noncombustible
Material
CombustibleWallMaterial
Noncombustible material must overlap Cabinet
ApronPanelwhenBackerPlateisnotused.
Cabinet Apron Panel
Finished non-combustible wall facing,
tile, cultured stone, etc.
4.4 Surround Treatments
4.4.1BackerPlate
The Backer Plate is useful for obscuring seams between
the fireplace cabinet and the surrounding wall facing
materials. The Face Plate is always used with the Backer
Plate.
4.4.2FacePlate
The Face Plate can be used alone but will require that the
CabinetApronPanelbecoveredwithnon-combustible
material before non-combustible finish material is applied.