4.0 Installation
4.1 Electrical Requirements
Thisappliancerequires120VAC,4ampsforoperationof
theBlower,AccentLamp,andRemoteControlfunctionality.
Thisappliancepowersupplymustbeelectrically
groundedinaccordancewithlocalcodesor,inthe
absenceoflocalcodes,withthecurrentANSI/NFPA70,
National Electrical Code or CSA C22.1-Canadian Electri-
cal Code.
Donotdisconnectthelampandfanpowercordsfrom
theappliancepowersupply(FanControlModule).Use
therockerswitchtocontrolpowertotheseparts.
AlwaysturnoffthemainpowersupplyattheFanCon-
trolModulewhenperformingroutineserviceonthis
appliance.
NOTE: Fireplace control components may be adversely
affected by other electrical controls that share the
same circuit. If it is not practical to install a dedicated
servicelinetothefireplace,werecommenduseofa
circuitthatisfreeofdimmersand/orfanspeedcon-
trols.
4.2 Fireplace Location
In selecting a location for the fireplace, consider the
following points:
1) Heat distribution
2)Ventterminationrequirements
3) Gas supply routing
4)Trafficareas,furniture,draperies,etc.
5)120Velectricalserviceavailability.
This fireplace may be located on or near conventional
construction materials, however, proper clearance to
combustibles must be maintained in order to provide
adequate air circulation around the appliance. Follow the
framing and clearance specifications exactly.
The clearances specified in this manual are the mini-
mum requirements established as a result of safety test-
ing. A combustible material is anything that can burn; i.e.
sheet rock , wall paper, wood, fabrics, etc. These surfaces
are not limited to those that are visible and also include
materials that may be located behind non-combustible
materials.
If you are not sure of the combustible nature of a
material,consultyourlocalfireofficials.“Fire-resistant”
materials are considered to be combustible. They may be
difficulttoignite,butwillburn.“Fire-rated”sheetrockis
also considered combustible.
20 FT. MAX.
20 FT. MAX.
Island
ParalleltoCornerParallel to Wall
Corner
RoomDivider
ExteriorChase
Figure 4.1. Fireplace locations - Top Vent. This figure is
for illustrative purposes only. See pages 8 - 11 for specific
clearance and venting requirements.