Specifications

Purchase order no. 7/EDP/COMP/106 Dated : 30/09/2011
5
S.
No.
DESCRIPTION
Quantity
UNIT
PRICE
inclusive
of Excise,
Custom
Duty,
Freight &
Forwardin
g,Insuran
ce,
Installatio
n &
Commissi
oing
Charges
CST /
ST (In
Figure)
Service
Tax (In
Figure)
Total Unit
Price F.O.R
Destination
incl. of
CST/ST,
Service Tax,
,Freight
&Forwardin
g, Custom
Duty,
Insurance,
Installation
&
Commissioi
ng Charges
etc.
Total
Amount
F.O.R
Destination
incl. of
CST/ST,
Service
Tax, Freight
&Forwardin
g, Custom
Duty,
Insurance,
Installation
&
Commissioi
ng Charges
etc.
All figures in Rs.
1 2 3 4 5 6 7 8=7*3
50 ohms
Sine wave>6Vpp & <8Vpp no
load
Modem RJ-11 analog phone jack
Radio BNC, optional antenna required
for operation
Relays 2x, SPDT (Form C)
1.4
Cabinet/Chassis for Blade Servers with
following configuration
1 627000 31350 0 658350 658350
Chassis
Support for full height and half height blades in the
same enclosure holding upto 14 Intel Xeon
Servers. Same enclosure should support Intel
Xeon/AMD Opteron/RISC/EPIC based blades
Same enclosure should support server, storage
and expansion blades to enable consolidation of
hardware .Should support simultaneous housing of
Ethernet,FC,iSCSI,IB interconnect fabrics offering
Hot Pluggable & Redundancy as a feature for the
mentioned I/O devices
Ethernet Switch
Ethernet Switching Modules to be provided in
redundant configuration for Connecting to all the
blade servers to external Switch. Configuration
should help minimize the Ethernet Cables
SAS Channel Modules
The Blade Chassis should be configured with
redundant SAS SAN Switches.
Management Module
System Management Port to allow simultaneous
management access of multiple Blade Servers in
the Chassis.
GUI, console-based deployment server to set up
multiple OS and application configurations and
Drag-and-drop servers into configurations
Power Modules
The enclosure should be populated fully with
power supplies of the highest capacity available
with the vendor.
Power supplies should support N+N as well as
N+1 redundancy configuration, where N is greater
than 1.Should offer choice of a single phase or 3
phase power subsystem for flexibility in connecting
to datacenter power enabled with technologies for
lower power consumption.Guaranteeing complete
availability even on failure of any 2 power units
across the enclosure.
Cooling
Each blade enclosure should have a cooling
subsystem consisting of redundant hot pluggable
fans or blowers enabled with technologies for
improved power consumption and acoustics