Specifications
INTERTEK TESTING SERVICES
FCC ID: UVD20071228001
5
2.0 System Test Configuration
2.1 Justification
The system was configured for testing in a typical fashion (as a customer would
normally use it), and in the confines as outlined in ANSI C63.4 (2003).
For maximizing emissions below 30 MHz, the EUT was rotated through 360°,
the centre of the loop antenna was placed 1 meter above the ground, and the
antenna polarization was changed. For maximizing emission at and above 30
MHz, the EUT was rotated through 360°, the antenna height was varied from 1
meter to 4 meters above the ground plane, and the antenna polarization was
changed. This step by step procedure for maximizing emissions led to the data
report in Exhibit 3.0.
The unit was placed in the rear of the turntable.
The equipment under test (EUT) was configured for testing in a typical fashion
(as a customer would normally use it). The EUT was placed on a turn table,
which enabled the engineer to maximize emissions through its placement in the
three orthogonal axes.
The frequency range from 30MHz to 2GHz was searched for spurious emissions
from the device. Only those emissions reported were detected. All other
emissions were at least 20 dB below the applicable limits.
2.2 EUT Exercising Software
There was no special software to exercise the device. Once the unit is powered
up, it transmits the typical signal continuously.
2.3 Special Accessories
No special accessories were used for compliance of this product.
2.4 Equipment Modification
Any modifications installed previous to testing by Shenzhen MTC Co., LTD will
be incorporated in each production model sold/leased in the United States.
No modifications were installed by Intertek Testing Services