Specifications

INTERTEK TESTING SERVICES
FCC ID: UVD20071228001
24
Applicant: Shenzhen MTC Co., LTD Date of Test: March 19, 2008
Model: AT2016
Mode: Modulating
Table 4 Antenna Transfer Switch Measurement Pursuant to FCC Part 15
Section 15.115 Requirement
Channel
Frequency
(M Hz)
Reading
(dBµV)
Pre-am
p (dB)
Pad +
Pass
splitter
Loss
(dB)
Result
(dBµV)
Lim it
(dBµV)
Margin
(dB)
03 61.250 12.0 22.5 12.0 1.5 9.5 -8.0
04 67.250 11.8 22.5 12.0 1.3 9.5 -8.2
NOTES: 1. Test according to section 12.2.6 of ANSI C63.4
2. A pass splitter (6dB attenuation) and a 50 to 75 (6dB attenuation)
matching-impedance pad were employed.
3. Negative sign in the column shows value below limit.
4. The measuring instrument was set to 100kHz bandwidth and the
detector function to peak mode
5. Limit should not exceed 3.0µV or 9.5dBµV.
Test Engineer: Billy Li