Instruction manual
15 
Boiler overheating 
If the temperature of the boiler raises to more than 105 °C, the regulator stops the flue-gas fan and 
the control light of boiler overheating shines on. For new start it is necessary to: 
-  wait until the boiler temperature falls 
-  remove  the  cause  of  boiler  overheating  (e.g.  refill  missing  water  into  the  central  heating 
circuit) 
Warning! Water can be refilled only after the boiler temperature falls under 40°C. 
 - turn the button of the boiler thermostat into the maximum left position ad thus stop  the 
alarm 
- wait until the control light of boiler overheating starts flickering; 
- to start the regulator again, set up the required temperature of the boiler by the turning button of 
the thermostat; 
If the temperature falls under 60 °C, the regulator comes into the burning up mode. 
Methods of regulation of the ATTACK DPX PROFI boiler 
The boiler enables regulation of room temperature as well as connecting the sensor of room 
temperature. If the room temperature is lower than the set up one, the control light near the button 
of  thermostat  shines  on,  which  means  that  the  boiler  must  keep  the  set  up    temperature.  After 
reaching the required temperature the control light switchces off, the suction fan switches off and 
the boiler starts burning at the temperature of 65 °C. 
For the purposes of timing  regulation by room temperature it is possible to connect any arbitrary 
programmable thermostat with the terminals for the sensor of  room temperature. In this case, the 
turning button of the room thermostat is not working. 
If you do not wish to use the room thermostat nor the room sensor, the inlet terminals must  be 
short-circuited. In this case only the boiler thermostat is working. 
 The mixing valve with the electric drive can be also connected to the boiler regulator . (This system 
is not standardly delivered with the boiler). 
Error messages  
The boiler regulator constantly verifies the functions of internal systems and of the sensor of  boiler 
temperature. After  finding out  the  defect, the  regulator switches off  the  flue-gas  fan, the  central 
heating pump and at the same time the defect shows on the display. In the case of breakdown it is 
necessary  to  switch  the  boiler  off  by  the  main  switch,to  assure  the  continuous  operation  of  the 
central  heating  pump   by  plugging  into  the  mains,  the  fuel  must  be  burnt  thoroughly  and  the 
contract service company contacted. 
If  E1 fault   appears on  the  display, it means the    damage of  the  sensor of  boiler  temperature. 