Instruction manual
24 
automatically. During this test, it is necessary to hold the + button  within 30 seconds, to prevent 
automatic stop of the test (see explanation in the schedule below). 
Test is time limited for 30 minutes. It is automatically stopped or aborted if: 
1.  Boiler temperature increases to 110°C 
2.  The + button was not held for 30 seconds 
 In this case, regulator automatically switches to operation display. 
Menu  Submenu  Indication 
Information 
Test of device     
  Test is time limited for 30 minutes 
Safety test 
Safety test + 
(sec.) 30 
Boiler temperature 
(°C ) --,- 
After selection of the test, it is necessary to 
hold  the  +  button  within  30  seconds, 
otherwise is the test automatically stopped. 
If the boiler temperature increases to  95°C 
-  100°C,  the  STB  is  switched  on  and  the 
fan is switched off. After few seconds, the 
text:  „STB  on“  appears  on  display.  It 
means, that the STB test was successfully 
done. 
After  pressing  the  „+“  button  again, 
circuiting  pump  stays  stopped,  until 
temperature  of  110°C  is  reached,  to 
perform the test of overheating protection. 
Boiler  temperature  must  be  kept  under 
110°C  to  confirm,  that  the  test  of 
overheating  protection  was  successfully 
done or finished. 
Setting     
FINISH     
Maintenance of the heating system and of the boiler 
At  least  once  in  fortnight  check   or  fill  up    water  in  the  heating  system.  If  the  boiler  is  out  of 
operation during winter, water can be frost in the system. Therefore it is better to discharge water of 
the system or fill in the antifreeze agent. Otherwise discharge water only in critical situations and 
for the shortest possible time. After heating season is finished, clean the boiler thoroughly, replace 
damaged parts. Twice a year clean the radial impeller of the ventilator and its air chamber. 
Changing of door sealing cord 
Dismantle the old sealing cord with a screwdriver and clean the rabbet where it was placed. Take 
the new sealing cord and put its begining on the horizontal parts of the rabbet.  Press it into the 
rabbet on the circumference of the door with your hand or light knock of the hammer. 
Adjustment of hinges 
After some time, the sealing cord in the door gets deformed. Therefore, to ensure tightness of the 
door, it is necessary to change the position of the door. The position is changed by tightening the 
hinges of the door. Feeding door and bottom door are joined to the body with two hinges which are 
attached to the door with a long pin. To change adjustment of  hinges, it is necessary to remove the 
pin and screw the hinge by turning it. Fit the door on and insert the pin into the hinge. 
Nozzle body change 
The body of nozzle is placed in the boiler body in  a nozzle holder. In the  lower part  is the nozzle 
body sealed by  boiler lute and in the upper part by a packing cord. When exchanging the nozzle, 