Boiler connection to the electricity mains 
The boiler is connected to the mains of 230 V/50 Hz by a supply cord and plug. The voltage is of M 
type and when replaced, the same type must be used by a  service oragnization.The appliance must 
be located in such a way that the plug was within the reach of the attendance. 
(under STN EN 60 335-1 + A11:1997). 
Selection and method of connection of regulation and control elements 
Boiler is supplied  with basic equipment of regulation and control elements. Connection of these 
elements is given in the scheme of connection. It is recommended to extend boiler regulation with 
other  regulation  elements  that  enable  more  comfortable  and  more  economical  operation.  Every 
pump in the systme must be controlled by individual thermostat to prevent boiler undercooling at 
the return water inlet (C.H. return connection) under 65°C. 
Connection of these additional elements is planned by projectant, adequately to specific conditions 
of the heating system. Electric installation connected to sufficient boiler equipment must be done by 
specialist, in conformity with valid norms. 
Warning: heating system must be equipped with safety valve against overpressure. 
Boiler protection against 
corrosion 
Suitable  solution  of  this  problem  is 
usage  of  mixing  device  (Regumat 
Attack-Oventrop). Both solutions enable 
creation of separate boiler and  heating 
circuit.  Thereby  it  is  prevented  from 
boiler undercooling under 65°C and the 
condensation of water steams, acids and 
tars  in  the  boiler  hopper  is eliminated. 
Mixing  device  Regumat  keeps  constant 
temperature  of  return  heating  water, 
enetring  into boiler  at 65°C,  when  the 
thermostatic  head  is  set  to  5th-6th 
degree.  At  usage  of  individual thermal 
regulation  valve,  it  is    possible  to 
regulate  heating  water  temperature  by 
setting  of  the  flap,  independently  from 
temperature of water in the boiler. Temperature in the boiler has to be kept in the range of 80-90°C. 
Technical parameters REGUMAT ATTACK OVENTROP: 
Clarity DN 25 
Maximum pressure 10 bar 
Maximum temperature 120°C 
Value kvs 3,9 
Clarity DN 32 
Maximum pressure 10 bar 
Maximum temperature 110°C 
Value kvs 0 