Instruction manual
45 
Oxygene probe (Lambda sonda) 
4-conductor silicone-covered flexicord 
with conductor´s crossection of 0,75mm2 
white = warming 12V
black= + signal of probe
grey = - signal of probe
~
Probe
Probe
Probe warming
Probe
Probe 1:  Probe -
Probe 2:  Probe +
Probe 3:  Probe warming
Probe 4:  Probe warming
Temperature sensor 
Terminal 1: Flue gas sensor F1 Pt100  Mount the flue gas sensor into the flue gas connection by  the 
bayonet flange!
Terminal 2: Flue gas sensor F1 Pt100
Terminal 3: Boiler sensor F2 Pt100  Do not extend connection conductor´s of sensors!!!
Terminal 4: Boiler sensor F2 Pt100  
Terminal 5: 
Terminal 6: 
Values of resistance:
Boiler sensor and sensor of safety thermostat have to be 
treated with warmwater paste, put into gasket and tighten by 
holding spring!
Polarity is irrelevant
Air flapV1 – V2, circuiting pump, suction fan 
For connection of circuiting pump and 
suction fan, use 3-conductor flexicord 
with conductor´s cross section of 
0,75mm2!
C: SHADING CONDENSATOR
Terminal 3: Connection
Terminal 4: Connection 24V~
Terminal 5: Regulation signal secondary   
Terminal 6: 
┴
Y+(0/2-10V)
Regulation signal primary Y+(0/2-10V)
Terminal 12: L: Circuiting pump
Terminal 13: N: Circuiting pump
Terminal 14: PE: Circuiting pump
Terminal 15: L: Suction fan
Terminal 16: N: Suction fan
Terminal 17: L: Free
Terminal 18: PE: Suction fan