Technical information
7 - Control light of C.H. pump operation.
8 - Control light of fuel shortage
9 - Knob of room /flue gas
thermostat
10 -Button TEST (by pressing it, the
temperature set by knob 6 appears and
the flue gas fan is stopped for a while at
the same moment)
1 - Main switch
2 - Display showing boiler
temperature
3 - Control light of heating-up
process
4 - Control light of boiler overheating
5 - Control light of boiler
thermostat
6 - Knob of boiler
thermostat
Rear view at electronic regulator:
Output level of the
flue gas fan
at boiler heating-up
Intensity of the fan operation when the heating water temperature is reached
Fuse
2A
Connection of
the mixing valve
(12 V)
Connection of the room temperature sensor
ATTACK DPX LAMBDA
Wood gasifying boiler „ATTACK DPX Lambda“ uses the most advanced technology for combustion process control to achieve
the excellent values of emissions and efficiency. Regulation can separately control amount of inlet primary and secondary air in
accordance to data about oxygene content from the Lambda probe, boiler temperature and flue gas temperature. All operation
parameters are displayed on well-readable multi-line LCD display.
It is possibile to change parameters by buttons on the boiler control board. Eventual error or warning messages are signalized by
LED diodes.
After the fuel bun-down is the boiler automatically switched off adequately to flue gas temperature or percentual oxygene content
in flue gas. All modifications of the ATTACK DPX boilers can be equipped with addtional regulator that ensures control of
accumulation tank, solar panels or ther sources of heat energy in different designes of heating systems following the customer´s
request.
2 1 83 4 5 6 7
Description:
1: Lights after boiler start by the „+“ (5) , expires after fuel burn-down or by manual stop by the „-“ (6) button
2: Lights in case of the following errors: - incorrect value of flue gas temperature
3: Lights or flickers in accordance to the fault importance:
Reset - lights, Incorrect boiler temperature- lights, Too high boiler temperature -flickers , Boiler overheating - do not open
(boiler temperature over 90°C) - flickers
4: Displays operation data enables browsing in menu. If the boiler is out of order for more than 15min and no error is
displayed, display illumination is automatically shut down.
5: Display illumination is turned on. After repated pressing is boiler started or fuel loading is enabled.
6: Serves for emergency boiler stop. It is used only in case that there is no water in the system or the sensor for
overheating does not work.
7: Serves for enter into menu and confirmation of the set value.
8: Button of safety boiler protection against overheating.
If temperature of boiler water exceeded 95°C, the boiler is stopped. It is possible to turn the boiler on, only when the
temperature decreases.
button
11 - Thermomanometer
1 - Control light of boiler operation
2 - Control light of error messages
3 - Control light of warning messages
4 - Multi-line LCD display
5 - Button of boiler start and parameter change
6 - Button of boiler stop and parameter change
7 - Enter ( button to confirm and to enter into
menu )
8 - Reset
9 - Thermomanometer
9