User Manual

7
8
The brackets for the handles must be installed when operating for the first time.
Please see the following illustration:
1. Please fix the bracket by tightening the four screws according to the illustration
and your personal habit.
2. According to your selection, dismantle the two screws on the left or the right,
which fix the bracket of the handle.
3. Place the two installation hole of the bracket to the two fixed screw holes of the
machine, and then tighten the dismantled two screws. Put the components of the
handle on the bracket to check if it is suitable.
Installation:
Introduction for LCD display:
A screen (rework station, same as below) B screen (soldering station, same as below)
Display "- - -" means the device is standby
Screen "A" displays the working state of rework station.
"P_ _" eans rework station is under the normal setting condition.
" P 0 1 " means rework station is under the condition set by memory group 1.
" P 0 2 " means rework station is under the condition set by memory group 2.
" P 0 3"means rework station is under the condition set by memory group 3.
Both screen A and screen B display " OFF" in the memory temperature area 2,
which means the device, is standby.
When the temperature area shines the station is under the condition
available to set.
Description for LCD display
Upon power on the unit, the reworking station and soldering station be standby.
Power:
Standby state of screen A Standby state of screen B
(diagram 1) (diagram 2)
. REWORK STATION
1. Power on: Rework station start to work after press the "POWER" knob at the
left of panel.
2. At that time, if the handle is on the bracket, screen "A" display state standby
(diagram 3), or display the setting temperature and 3 seconds later it display
the actual temperature (diagram 4, diagram 5).
(diagram 3) (diagram 4) (diagram 5)
Screen A: Standby
Screen A:
Setting Temperature
Screen A:
Actual Temperature
3. Temperature Settings
In normal condition, there are two methods to set temperature of hot-air
reworking station.
A. If screen A shines setting temperature through operating the
button of panel. If screen A doesn't shine you must press the
"SET"button to switch to shine of screen A then the station
Display of status
Setting value and display
of real temperature
Temperature unit
Power direction
Working mode
Setting temp.
Air flow display
Display of status
Temperature unit
Power direction
Setting value and display
of temperature